Data Domain: NVRAM Hardware Failure Alert | EVT‑NVRAM‑00201

Summary: This article describes the conditions that trigger the 'NVRAMHardwareFailure' alert on Data Domain systems and outlines the required resolution steps.

Ez a cikk a következő(k)re vonatkozik: Ez a cikk nem vonatkozik a következő(k)re: Ez a cikk nem kapcsolódik egyetlen konkrét termékhez sem. Ez a cikk nem azonosítja az összes termékverziót.

Symptoms

A Critical alert is generated indicating an NVRAM hardware failure. When this alert is present:

  • The NVRAM card is considered unusable or unreliable.
  • The Data Domain file system cannot be accessed until the issue is corrected.
  • System operation may be blocked or degraded.

Alert Details:

  • Alert ID: EVT‑NVRAM‑00201
  • Severity: Critical
  • Class: hardwareFailure
  • Object: Slot=%s
  • Message:
    “A hardware fault was detected with an NVRAM card and it may need to be replaced.”

Applies to:

  • All Data Domain systems
    • For systems (DD9910,DD9410, DD6410, DD9910F) with Software Defined Persistent Memory (SDPM) See KB: Data Domain: How to Diagnose and Resolve SDPM | NVRAM Alerts  
      • SDPM-NVRAM errors also trigger the DDOS NVRAM-00201 Alert - analysis into the related iDRAC error code is required (part replacement may not be needed).
  • All Software/DDOS versions

Cause

The NVRAMHardwareFailure alert is triggered when the system detects a hardware condition that renders the NVRAM card unusable. These conditions fall into two categories:

  1. Configuration issues detected during system boot
  2. Hardware component failures detected during boot or normal operation

If multiple failures are detected simultaneously, the alert reports:
"Multiple NVRAM hardware failures."

Examples of conditions that may trigger this alert include (but are not limited to):

  • NVRAM card not detected
  • Unsupported or mixed NVRAM card types
  • Incorrect number of NVRAM cards for the platform
  • NVRAM card and DDR model mismatch
  • Inability to retrieve NVRAM card or battery information
  • Excessive correctable or uncorrectable NVRAM memory errors
  • NVRAM device operating in read‑only mode
  • Incorrect NVRAM memory size, PCIe link speed, or link width
  • Critical voltage rail conditions affecting NVRAM components

Specific failure details are provided in the alert field:
Info: Cause=%s

Resolution

  1. Run offline diagnostics or system healthcheck to confirm the NVRAM failure.
    • Useful Commands:
      • # alerts show current
      • # system show nvram
      • # support healthcheck hardware | # system health check
      • # system show hardware
  2. Correct any placement or configuration issues if applicable.
  3. If the NVRAM is PCIe-based (All-in-one) - replace the NVRAM card if diagnostics confirm a hardware failure.

If assistance is required, contact your contracted support provider - Dell Tech Support

Érintett termékek

Data Domain

Termékek

Data Domain
Termék tulajdonságai
Article Number: 000011063
Article Type: Solution
Utoljára módosítva: 27 júl. 2026
Version:  7
Választ kaphat kérdéseire más Dell-felhasználóktól
Támogatási szolgáltatások
Ellenőrizze, hogy a készüléke rendelkezik-e támogatási szolgáltatással.