VPLEX:分散式裝置層次結構缺少範圍

Summary: 本文討論分散式設備層次結構缺少擴展數據塊的問題以及如何解決缺少的擴展數據塊。

Ez a cikk a következő(k)re vonatkozik: Ez a cikk nem vonatkozik a következő(k)re: Ez a cikk nem kapcsolódik egyetlen konkrét termékhez sem. Ez a cikk nem azonosítja az összes termékverziót.

Symptoms



查看分散式設備的元件層次結構時,設備支線缺少擴展數據塊。

VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
  consistency-group: CG-CS-Test (synchronous)
    virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
      distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
        distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
          extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
            storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
              logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
                storage-array: EMC-CLARiiON-APM00xxxxxxxxx
        distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1)

                                                                                                                                            <-- The missing extent is expected here.
          storage-volume: CLARiiON1234_LUN_00030 (1G)
            logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
              storage-array: EMC-CLARiiON-APM00xxxxxxxxx



列出分散式設備元件時,其中一個元件將顯示為幾何為「切片」的範圍。

VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/

/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name                                Cluster    Child  Fully   Operational  Health  Block   Block  Capacity  Geometry  Total
----------------------------------  ---------  Slot   Logged  Status       State   Count   Size   --------  --------  FreeSpace
----------------------------------  ---------  -----  ------  -----------  ------  ------  -----  --------  --------  ---------
device_C2_CLARiiON1234_LUN_00015_1  cluster-2  1      true    ok           ok      262144  4K     1G        raid-0    -
extent_CLARiiON1234_LUN_00030_1     cluster-1  0      true    ok           ok      262144  4K     1G        slice     - <-- N
ote the "Geometry" for this extent is listed as 'slice'.

 

Cause

在極少數情況下,由於磁碟區上有範圍遷移,可能會發生此問題。遷移完成後,元件層次結構中的擴展數據塊頂部缺少 R0 (RAID 0) 設備。

Resolution

元件層次結構中缺少 R0 設備是外觀問題。將裝置保留在此狀態,不會對 VPLEX 作業產生任何明顯影響。但是,如果需要解決此外觀問題,請向 VPLEX 支援開立服務要求,並提及本文。

此顯示問題的解決方案是使用內部韌體命令,在範圍上方插入新的 R0 裝置。此程序不會造成任何影響,但只能由技術支援人員完成。

永久修正:
由於這是外觀問題,因此目前沒有永久修正。

Additional Information

Érintett termékek

VPLEX Series

Termékek

VPLEX for All Flash, VPLEX GeoSynchrony, VPLEX Series, VPLEX VS2, VPLEX VS6
Termék tulajdonságai
Article Number: 000167451
Article Type: Solution
Utoljára módosítva: 05 szept. 2025
Version:  4
Választ kaphat kérdéseire más Dell-felhasználóktól
Támogatási szolgáltatások
Ellenőrizze, hogy a készüléke rendelkezik-e támogatási szolgáltatással.