VPLEX:分布式设备层次结构是缺失的扩展区

Summary: 本文讨论分布式设备层次结构缺少数据区的问题,以及如何解决数据区缺失的问题。

Ez a cikk a következő(k)re vonatkozik: Ez a cikk nem vonatkozik a következő(k)re: Ez a cikk nem kapcsolódik egyetlen konkrét termékhez sem. Ez a cikk nem azonosítja az összes termékverziót.

Symptoms



查看分布式设备的组件层次结构时,设备分支缺少扩展区。

VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
  consistency-group: CG-CS-Test (synchronous)
    virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
      distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
        distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
          extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
            storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
              logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
                storage-array: EMC-CLARiiON-APM00xxxxxxxxx
        distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1)

                                                                                                                                            <-- The missing extent is expected here.
          storage-volume: CLARiiON1234_LUN_00030 (1G)
            logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
              storage-array: EMC-CLARiiON-APM00xxxxxxxxx



列出分布式设备组件时,其中一个组件将显示为几何结构为“切片”的扩展区。

VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/

/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name                                Cluster    Child  Fully   Operational  Health  Block   Block  Capacity  Geometry  Total
----------------------------------  ---------  Slot   Logged  Status       State   Count   Size   --------  --------  FreeSpace
----------------------------------  ---------  -----  ------  -----------  ------  ------  -----  --------  --------  ---------
device_C2_CLARiiON1234_LUN_00015_1  cluster-2  1      true    ok           ok      262144  4K     1G        raid-0    -
extent_CLARiiON1234_LUN_00030_1     cluster-1  0      true    ok           ok      262144  4K     1G        slice     - <-- N
ote the "Geometry" for this extent is listed as 'slice'.

 

Cause

在极少数情况下,卷上的扩展区迁移可能会导致此问题。迁移完成后,组件层次结构中的扩展区顶部缺少 R0 (RAID 0) 设备。

Resolution

组件层次结构中缺少 R0 设备是表面问题。将设备保留在此状态不会对 VPLEX作产生任何明显影响。但是,如果需要解决此表面问题,请向 VPLEX 支持部门提出服务请求并提及本文。

此显示问题的解决方法是使用内部固件命令在数据区顶部插入新的 R0 设备。此过程不会造成任何影响,但只能由技术支持人员完成。

永久修复:
由于这是一个表面问题,目前没有永久的修复方法。

Additional Information

Érintett termékek

VPLEX Series

Termékek

VPLEX for All Flash, VPLEX GeoSynchrony, VPLEX Series, VPLEX VS2, VPLEX VS6
Termék tulajdonságai
Article Number: 000167451
Article Type: Solution
Utoljára módosítva: 05 szept. 2025
Version:  4
Választ kaphat kérdéseire más Dell-felhasználóktól
Támogatási szolgáltatások
Ellenőrizze, hogy a készüléke rendelkezik-e támogatási szolgáltatással.