PowerStore: System Check detects unnecessary de-stages

Summary: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.

Ez a cikk a következő(k)re vonatkozik: Ez a cikk nem vonatkozik a következő(k)re: Ez a cikk nem kapcsolódik egyetlen konkrét termékhez sem. Ez a cikk nem azonosítja az összes termékverziót.

Symptoms

If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"

Screenshot of the PowerStore Manager:image.png

When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check
Name                               Location  Status     Description
Datapath Dedup Destage Leak        node_a    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
Datapath Dedup Destage Leak        node_b    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
 
 
SUMMARY Status: Failed
   Passed:      0
   Failed:      2
   Total:       2
 

Cause

The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.

The issue is resolved in 3.6 and later.

Resolution

If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.

Additional Information

Érintett termékek

PowerStore
Termék tulajdonságai
Article Number: 000220203
Article Type: Solution
Utoljára módosítva: 14 jún. 2025
Version:  3
Választ kaphat kérdéseire más Dell-felhasználóktól
Támogatási szolgáltatások
Ellenőrizze, hogy a készüléke rendelkezik-e támogatási szolgáltatással.