PowerStore: System Health Checks detects wrong Data Path memory settings

Summary: This System Health Check (SHC) detects wrong Data Path (DP) memory settings.

Ez a cikk a következő(k)re vonatkozik: Ez a cikk nem vonatkozik a következő(k)re: Ez a cikk nem kapcsolódik egyetlen konkrét termékhez sem. Ez a cikk nem azonosítja az összes termékverziót.

Symptoms

System Health may display a Datapath memory override file exists. (KB#000253246) message in one of the following scenarios:

  • Running a System Check using PowerStore Manager (GUI) with the Run System Check option:dp_mem_allocation_override_check SHC failed 
  • Running the System Health Service Script (dp_mem_allocation_override_check) using an SSH connection:
    [BSC:cyc@8SP3DN3-A ~]$ svc_health_check run -rhc dp_mem_allocation_override_check
    Name                  Location  Status     Description
    Datapath memory allo.. node_a   Failed     Datapath memory override file       
                                               exists. (KB#000253246)              
    Datapath memory allo.. node_b   Passed                                         
     
     
    SUMMARY Status: Failed
       Passed:      1
       Failed:      1
       Total:       2
  • If this SHC detects that DP is running with non-default DP memory settings, PowerStore Manager displays: SHC detects that DP is running with non-default mem settings
  • In this case, the following output is displayed when running the System Health Service Script (dp_mem_allocation_override_check) using an SSH connection:
    [BSC:cyc@8SP3DN3-A ~]$ svc_health_check run -rhc dp_mem_allocation_override_check
    Name                  Location  Status     Description
    Datapath memory allo.. node_b   Passed                                         
    Datapath memory allo.. node_a   Failed     Datapath memory settings do not     
                                               match default settings.             
                                               (KB#000253246)                      
     
    SUMMARY Status: Failed
       Passed:      1
       Failed:      1
       Total:       2

Note: Results may vary based on the node where the check failed.

The health check is an off-release SHC check that is contained in the Health Check thin package. See the Additional Info section of this article for information about the Health Check thin package.

Cause

Impact

Wrong DP memory configuration can cause DP to fail. 

Resolution

To resolve this issue, contact technical support for assistance. Reference KB# 000253246 for expedited attention and resolution.

Additional Information

Érintett termékek

PowerStore
Termék tulajdonságai
Article Number: 000253246
Article Type: Solution
Utoljára módosítva: 14 jún. 2025
Version:  3
Választ kaphat kérdéseire más Dell-felhasználóktól
Támogatási szolgáltatások
Ellenőrizze, hogy a készüléke rendelkezik-e támogatási szolgáltatással.