VxRail: VMware vCenter Server konnte beim Exportieren von Daten von der Quell-VM nicht aktualisiert werden
Summary: Während eines Upgrades von VxRail vCenter Center schlug dieses fehl, wenn Daten vom Quell-vCenter-Server auf den Ziel-vCenter-Server exportiert wurden. Aus dem Protokoll geht hervor, dass viel Zeit für das Exportieren von VMware Analytics Service-Daten aufgewendet wurde. ...
Ez a cikk a következő(k)re vonatkozik:
Ez a cikk nem vonatkozik a következő(k)re:
Ez a cikk nem kapcsolódik egyetlen konkrét termékhez sem.
Ez a cikk nem azonosítja az összes termékverziót.
Symptoms
Von VxRail
lcm-web.logaus:
2025-08-31T10:27:25.367Z <4304e36e4934ff08fc8120c70e58301b> lcm [WARN] <183> VirtualApplianceUpgradeService.java runUpgrade() (1158): LCM Exception occurred during upgrade for virtual appliance 0 - {}
com.vce.lcm.exception.LCMException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.api.LCMServiceImpl.handleUpgradeException(LCMServiceImpl.java:2129)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:509)
at com.emc.mystic.manager.upgrade.service.VirtualApplianceUpgradeService.runUpgrade(VirtualApplianceUpgradeService.java:1134)
at com.emc.mystic.manager.upgrade.service.PureUpgradeRestServiceImpl.lambda$retryVirtualApplianceUpgrade$0(PureUpgradeRestServiceImpl.java:129)
at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:515)
at java.base/java.util.concurrent.FutureTask.run(FutureTask.java:264)
at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1128)
at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:628)
at java.base/java.lang.Thread.run(Thread.java:829)
Caused by: com.vce.lcm.exception.LCMInternalException: Failed to upgrade the VMware vCenter Server: Failed to export data from source VM VCENTER01.
at com.vce.lcm.core.upgrade.ComponentUpgradeService.performComponentUpgrade(ComponentUpgradeService.java:339)
at com.vce.lcm.api.LCMServiceImpl.performComponentUpgrade(LCMServiceImpl.java:2439)
at com.vce.lcm.api.LCMServiceImpl.performCompositeUpgrade(LCMServiceImpl.java:1845)
at com.vce.lcm.api.LCMServiceImpl.performUpgrade(LCMServiceImpl.java:507)
... 7 common frames omitted Vom /var/log/vmware/upgrade/export.json Protokoll des neu entwickelten vCenter Servers schlug das Upgrade fehl, wenn "Exporting VMware Analytics Service data..." mit TIME_OUT Error:
{
"progress": 37,
"progress_message": {
"id": "ur.upgrade.script.export.progress.text",
"translatable": "Exporting %(0)s data...",
"args": [
"VMware Analytics Service"
],
"localized": "Exporting VMware Analytics Service data..."
},
"status": "error",
"info": [],
"warning": [],
"question": null,
"error": {
"detail": [
{
"id": "ur.upgrade.execution.timedout.text",
"translatable": "Upgrade phase timed out. The time planned for the upgrade phase was %(0)s minutes. The upgrade phase has already been running for %(1)s minutes.",
"args": [
60,
60
],
"localized": "Upgrade phase timed out. The time planned for the upgrade phase was 60 minutes. The upgrade phase has already been running for 60 minutes."
}
],
"componentKey": "upgrade_framework",
"problemId": null,
"resolution": {
"id": "ur.upgrade.execution.timedout.resolution",
"translatable": "To extend the default timeout, set environment variable %(0)s for export upgrade phase, %(1)s for import upgrade phase, and %(2)s for import historical data phase. The timeout is in minutes.",
"args": [
"UPGRADE_EXPORT_TIMEOUT",
"UPGRADE_IMPORT_TIMEOUT",
"UPGRADE_POST_IMPORT_TIMEOUT"
],
"localized": "To extend the default timeout, set environment variable UPGRADE_EXPORT_TIMEOUT for export upgrade phase, UPGRADE_IMPORT_TIMEOUT for import upgrade phase, and UPGRADE_POST_IMPORT_TIMEOUT for import historical data phase. The timeout is in minutes."
}
},Cause
Dieses Problem tritt auf, weil der Push-Telemetrieprozess eine übermäßige Anzahl von Anforderungen mit eindeutigen IDs sendet, was zur Erstellung vieler Dateien im "/var/log/vmware/analytics/prod"-Verzeichnis. Manchmal hat dies zu einer Anhäufung von 185.000 bis 375.000 Dateien geführt.
Resolution
Siehe KB https://knowledge.broadcom.com/external/article/322053/vcenter-server-upgrade-from-70-to-80-fai.html (externer Link)
- Stellen Sie über SSH eine Verbindung zum vCenter-Quellserver her
- Führen Sie den folgenden Befehl aus, um die Anzahl der Dateien zu überprüfen, die auf dem vCenter Server aufgrund des Telemetrie-Push-Prozesses erstellt wurden:
ls /var/log/vmware/analytics/prod | wc -l - Laden Sie die
cleaning_vddk_script.shSkript aus dem Abschnitt Anhänge dieses Artikels. - Laden Sie das Skript in vCenter hoch und weisen Sie mit diesem Befehl Ausführungsberechtigungen zu:
chmod +x cleaning_vddk_script.sh - Führen Sie das Skript aus:
./cleaning_vddk_script.sh - Starten Sie das Upgrade über das VxRail-Plug-in neu.
Érintett termékek
VxRail, VxRail Appliance SeriesTermék tulajdonságai
Article Number: 000372265
Article Type: Solution
Utoljára módosítva: 31 okt. 2025
Version: 3
Választ kaphat kérdéseire más Dell-felhasználóktól
Támogatási szolgáltatások
Ellenőrizze, hogy a készüléke rendelkezik-e támogatási szolgáltatással.