Data Domain: Troubleshooting Memory Errors
요약: This article describes how to troubleshoot memory-related alerts on Dell Data Domain systems, including how to identify a faulty DIMM that requires replacement. It covers common alert codes, root causes of correctable and uncorrectable ECC errors, and step-by-step resolution guidance such as initiating POST-Package Repair (PPR), running diagnostic CLI commands, and performing physical troubleshooting. ...
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
- DDOS generates memory-related alerts, including:
DIMM-00001: Correctable ECC logging limit reachedDIMM-00002: Multibit uncorrectable ECC errorDIMM-00003: Memory card failureENVIRONMENT-00009: Correctable ECC errors exceed thresholdENVIRONMENT-00013: Uncorrectable ECC error detectedENVIRONMENT-00044: Memory riser fault detectedMEM-00001: DIMM failure detected; DDFS will not startMEM-00002: Memory size below configured value
- iDRAC System Event Log (SEL) reports
MEM0802:The memory health monitor feature has detected a degradation in the DIMM installed in DIMM [slot number]. Reboot system to initiate self-heal process.
- System reboots triggered by uncorrectable memory errors
- DDFS does not start or cannot be enabled
- System enters a down state due to memory hardware failure
- Other alerts may mask memory issues (for example, CPU Machine Check Error)
원인
- Data Domain DIMMs use Error Correcting Code (ECC) to detect and correct memory errors.
- Correctable errors accumulate and trigger alerts when thresholds are exceeded.
- Uncorrectable errors indicate a hardware fault and may cause system instability or reboot.
- Failure of a DIMM or memory riser reduces available memory and may prevent DDFS from starting.
🛠️ NOTE: Other symptoms or alerts may mask memory errors - for example, CPU Machine Check Error - a reboot may address the underlying memory issue and deeper log analysis or troubleshooting may be required.
해결
✅ NOTE: If an DIMM error is reported on Dell PowerEdge based systems, the first action to recover is to reboot the DataDomain unit. This will initiate PPR (POST Package Repair) to recover the DIMM.
DIMM Alert - Reboot Decision Guide
The BIOS Post Package Repair (PPR) feature can repair affected memory cells during a reboot.
Reboot decision guidance:
| Scenario | Recommendation |
|---|---|
| Alert just appeared; system stable; production backups running | Schedule a maintenance window within 24–48 hours to reboot the system |
| Alert present for multiple days without action | Schedule a reboot as soon as possible to avoid escalation to uncorrectable error (MEM0001) |
| System idle or in maintenance window | Reboot immediately to allow PPR self-heal |
Critical warnings:
- Do not remove or swap the DIMM before rebooting. PPR requires the original DIMM in place.
- The system may reboot automatically more than once during self-heal. This is expected behavior.
- If self-heal succeeds, DIMM replacement is not required.
- If the alert persists after reboot or escalates to MEM0001, contact Dell Support.
Standard Troubleshooting and Resolution Steps
- Reboot the Data Domain system (PowerEdge platforms) to initiate PPR.
- Identify the faulty component (DIMM, CPU, or motherboard) using alerts and diagnostics.
- Compare the current system state with a previous AutoSupport snapshot (before the alert).
- Run the following DD CLI commands:
alerts show current system show meminfo enclosure show memory log view debug/messages.engineering - Run DDOS Hardware Healthcheck to confirm the hardware fault.
- Perform physical checks:
- Reseat the DIMM securely
- Swap with a known good DIMM for isolation testing
- Replace the faulty component based on diagnostic results.
- If the system does not boot:
- Remove non-essential hardware
- Boot with a minimal configuration (single DIMM in slot 0)
- Collect a Support Bundle and open a Service Request if required.
- The following video shows how to gather a Support Bundle: Gather a Support Bundle
- The following video shows how to gather a Support Bundle: Gather a Support Bundle
추가 정보
References:
- PowerProtect and Data Domain Hardware Documents for relevant information about DIMM configuration and layout.
- Data Domain: System Memory Requirements and Expanded Storage Configurations
- Data Domain: Troubleshooting Memory Errors