PowerEdge: What is Predictive Drive Failure and How to Resolve It - PDR16
요약: This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss. ...
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
지침
What is Predicted Drive Failure and how to solve it?
Predictive drive failure alerts indicate that a hard disk may fail soon based on error trends detected by SMART monitoring or the RAID controller. This is a critical warning for storage health and should be addressed immediately to prevent data loss.
Typically the alert gets triggered by:
- Self-Monitoring, Analysis, and Reporting Technology
(SMART) detecting errors
Modern drives include extra space to reallocate bad blocks. However, if errors persist, the drive may need replacement.
Sometimes, firmware or reporting issues can cause false alerts, so updating firmware is recommended before replacing any hardware.
How To Troubleshoot Predictive drive failure?
Note: If multiple drives reporting PDR16 or SMART errors are seen, then contact Dell Support.
- Always perform a backup before any steps are taken.
- Predictive failure means that the disk could fail at any time. Ensure that all critical data is backed up before proceeding.
- Export a SupportAssist collection log that includes a controller log.
- Replace the hard drive (PD) and ensure the virtual disk (VD) is optimal.
Note:
- For hard drive replacement procedure, refer to PowerEdge: How To Install or Hot Swap a Replacement Hard Drive
- For Self-Dispatch service for your parts, browse How to use Self-Dispatch service for your PowerEdge server
- Perform firmware updates to:
- Hard Drive
- iDRAC
- RAID controller
- Note: Reboot is required to complete firmware install for a RAID card.
- More information about firmware update is located in the Dell article Updating Firmware and Drivers on Dell PowerEdge Servers.
More troubleshooting or maintenance may be required to ensure the health of the array.
Note: This article is part of the Server Tutorials: "RAID and Disks" available at PowerEdge Tutorials: Physical Disk Drives and RAID Controller (PERC) on Servers
해당 제품
C Series, Rack Servers, Tower Servers, XE Servers, XR Servers, iDRAC7, iDRAC8, iDRAC9, SupportAssist Enterprise, OEM Server Solutions, PowerFlex custom node, Poweredge FC430, Poweredge FC630, PowerEdge FC640, Poweredge FC830, PowerEdge FD332
, PowerEdge FM120x4 (for PE FX2/FX2s), PowerEdge M630, PowerEdge M630 (for PE VRTX), PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge M830, PowerEdge M830 (for PE VRTX), PowerEdge MX5016s, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840
...
제품
HS Series, Modular Infrastructure문서 속성
문서 번호: 000126418
문서 유형: How To
마지막 수정 시간: 09 12월 2025
버전: 33
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.