PowerFlex:裝置有修正讀取錯誤 - 重設裝置錯誤計數器
요약: SDS 裝置出現錯誤,指出「裝置有固定的讀取錯誤」。
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
- 當 SDS 裝置的讀取錯誤由 SDS 更正時,就會發生此問題。
- 當禁用或啟用後台掃描程式時,就會發生這種情況。
裝置上的固定錯誤顯示在以下位置:
-
GUI 顯示錯誤:

-
“
--query_sds --sds_id <SDS_ID>」輸出顯示每個裝置的計數器,並修正讀取錯誤:
15: Name: /dev/sdr Path: /dev/sdr Original-path: /dev/sdr ID: 2d63f7c80003000e
Storage Pool: SAS_pool1, Capacity: 1116 GB Error-fixes: 6 scanned 0 MB, Compare errors: 0 State: Normal
可使用 counters_dump.txt 在 MDM 中,getInfoDump 顯示 FIXED_READ_ERROR_COUNT 在不同的物件上:
ID: df7700a600120012 DEVICE_TYPE READ_ERR FIXED_READ_ERROR_COUNT 1 ID: 1d1e4e5500000012 SDS_TYPE READ_ERR FIXED_READ_ERROR_COUNT 1 ID: 1c34e1f700000007 STORAGE_POOL_TYPE READ_ERR FIXED_READ_ERROR_COUNT 1 ID: b9b286df00000001 PROTECTION_DOMAIN_TYPE READ_ERR FIXED_READ_ERROR_COUNT 1 ID: 49b6b8057d1fc84b SYSTEM_TYPE READ_ERR FIXED_READ_ERROR_COUNT 1
注意: MDM 事件記錄中沒有事件可指出已看到此「修正讀取錯誤」情況。
其他可能的癥狀:設備可能處於錯誤狀態。系統訊息或系統記錄中的區塊裝置上可能出現錯誤:
blk_update_request: critical medium error, dev sdr, sector 94390272 sd 0:2:15:0: [sdr] tag#1 FAILED Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE sd 0:2:15:0: [sdr] tag#1 Sense Key : Medium Error [current] sd 0:2:15:0: [sdr] tag#1 Add. Sense: Unrecovered read error
SDS 追蹤中可能會有很長的傳輸 I/O 訊息:
contDevMngr_HandleLongInflightIoViolation:02998: IO on devId: 2d63f7c80003000e (/dev/sdr) took too long, Low threshold exceeded - waited for reaper 12250 millis contDevMngr_HandleLongInflightIoViolation:02998: IO on devId: 2d63f7c80003000e (/dev/sdr) took too long, Low threshold exceeded - waited for reaper 13250 millis contDevMngr_HandleLongInflightIoViolation:02998: IO on devId: 2d63f7c80003000e (/dev/sdr) took too long, Low threshold exceeded - waited for reaper 14250 millis
SDS 中的裝置 I/O 計數器可能有錯誤 sdbg_out.txt:
13: Dev path:/dev/sdr Size(lbs):0 Time grn:520577464
Io Counters:
GENERAL
Writes: 4852 Lbs: 2160443 MBs: 1054 Errors: 0
Reads: 49283 Lbs: 111376 MBs: 54 Errors: 12744
BM
Writes: 0 Lbs: 0 MBs: 0 Errors: 0
Reads: 0 Lbs: 0 MBs: 0 Errors: 0
COMB_MAP
Writes: 5 Lbs: 1390 MBs: 0 Errors: 2
Reads: 0 Lbs: 0 MBs: 0 Errors: 0
TOOTH_MAP
Writes: 426 Lbs: 688528 MBs: 336 Errors: 424
Reads: 0 Lbs: 0 MBs: 0 Errors: 0
IO
Writes: 4319 Lbs: 603064 MBs: 294 Errors: 16
Reads: 2076 Lbs: 16608 MBs: 8 Errors: 22
裝置的延遲可能很高,根據 counters_dump.txt:
ID: 2d63f7c60003000c DEVICE_TYPE DEV_LATENCY AVG_WRITE_LATENCY_IN_MICROSEC 0 ID: 2d63f7c70003000d DEVICE_TYPE DEV_LATENCY AVG_WRITE_LATENCY_IN_MICROSEC 0 ID: 2d63f7c80003000e DEVICE_TYPE DEV_LATENCY AVG_WRITE_LATENCY_IN_MICROSEC 11424 ID: 2d63f7c90003000f DEVICE_TYPE DEV_LATENCY AVG_WRITE_LATENCY_IN_MICROSEC 0 ID: 2d63f7ca00030010 DEVICE_TYPE DEV_LATENCY AVG_WRITE_LATENCY_IN_MICROSEC 0
影響
「Fixed Read Errors」計數器對系統不會有任何直接影響
但是,它可能表示可能導致 SDS 中斷連線、重建活動等的基礎情況。
원인
當 SDS 裝置使用鏡像複本修正或修正的讀取錯誤時,會出現此問題。更正發生在以下情況下:
- 後台掃描程式無法讀取數據的一個副本,並使用另一個副本覆蓋它。
- SDS 由於無法讀取磁碟而無法處理 SDC 的讀取要求,而是使用次要複本來處理 I/O 並覆寫本機資料。
此警告表示磁碟可能正在變慢、發生壞機或具有損壞磁區。上述機制重寫塊,可以修復“軟”壞塊。
해결
- 檢查磁碟。如有必要,請與硬體供應商聯繫以進行更換。計數器通常會指出基礎狀況,且磁碟即將損壞。上述 SDS 動作是嘗試修正軟不良磁區,但並非在所有情況下都能成功。
- 使用管理員登入,從主要 MDM 執行下列命令,以清除錯誤計數器:
scli --reset_scanner_error_counters --protection_domain_id <pd id> --storage_pool_id <sp id> --reset_corrected_read_error_counter
您可以執行 scli --query_all 命令,以列出保護網域 和 儲存集區 ID。
문서 속성
문서 번호: 000174344
문서 유형: Solution
마지막 수정 시간: 24 7월 2026
버전: 9
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스