Dell Data Wipe (NIST 800-88r1, IEEE 2883-2022) Supported Storage Media Sanitize Actions

요약: Information about supported commands for Dell Data Wipe.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

증상

No symptoms information is available.

원인

No cause information is available.

해결

Dell Data Wipe Command Information.

In general, the sanitize requirements that are pasted below are manufacture implementation requirements. Dell Data Wipe issues the commands in the table below to the storage media.

The storage media manufacturer implements the wipe behavior to meet the National Institute of Standards and Technology (NIST) guideline and Institute of Electrical and Electronics Engineers (IEEE) standard. The BIOS is only issuing the command, and not directly telling the storage media how to perform the command. The BIOS does not control the storage media behavior once the wipe commands are issued to the media.

Depending on the media, different commands are issued. The result is a Purge, or a Clear, depending on the storage media type (Table 1).

Storage Media Commands Method NIST 800-88r1   Method IEEE 2883-2022  
PCIe/NVMe SSD - Non SED*   Sanitize Purge Purge
PCIe/NVMe SSD - SED* Sanitize Purge Purge
eMMC Erase and Sanitize Clear Clear
UFS Erase and Purge Purge Purge
ATA SSD Sanitize Purge Purge
ATA HDD Enhanced Security Erase   Purge Purge

*Self-Encrypting Drive
Table 1 - Storage Media Sanitization Commands.

NIST 800-88r1 guideline: NIST Special Publication 800-88 - Guidelines for Media Sanitization This hyperlink is taking you to a website outside of Dell Technologies. states the following:

Clear, Purge, and Destroy are actions that can be taken to sanitize the media. The sanitization categories are defined as:

  • Clear applies logical techniques to sanitize data in all user-addressable storage locations. For protection against simple noninvasive data recovery techniques; typically applied through the standard Read and Write commands to the storage device, such as by rewriting with a new value or using a menu option to reset the device to the factory state (where rewriting is not supported).
  • Purge applies physical or logical techniques that render Target Data recovery infeasible using state-of-the-art laboratory techniques.
  • Destroy renders Target Data recovery infeasible using state-of-the-art laboratory techniques and results in the subsequent inability to use the media for storage of data.

Back to Top

해당 제품

Alienware, Dell All-in-One, Dell Pro All-in-One, Dell Pro Max Micro, Dell Pro Max Slim, Dell Pro Max Tower, Dell Pro Micro, Dell Pro Slim, Dell Pro Tower, Dell Slim, Dell Tower, Inspiron, OptiPlex, Vostro, XPS, G Series, G Series, Alienware , Dell Plus, Dell Pro, Dell Pro Max, Dell Pro Plus, Dell Pro Premium, Inspiron, Latitude, Dell Pro Rugged, Vostro, XPS, Fixed Workstations, Mobile Workstations, Dell Pro Max Micro XE FCM2250, Dell Pro Max Slim XE FCS1250, Dell Pro Max Tower T2 XE FCT2250, Dell Pro Micro Plus XE QBM1250, Dell Pro Slim Plus XE5 QBS1250, Dell Pro Tower Plus XE5 QBT1250, OptiPlex 3000 Thin Client ...