VMAX AFA & PowerMax: VDM cannot load after DM panic due to blocked threads when running Embedded NAS 8.1.15.401 and NFSv4 mounted filesystem.

요약: VDM cannot load after a DataMover (DM) panic due to blocked threads, issue is when eNAS is running Version 8.1.15.401 and NFSv4 mounted filesystem.

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

증상

VDM cannot load after  a DataMover (DM) panic due to blocked threads, issue is when eNAS is running Version 8.1.15.401 with NFSv4.

From the Logs: 

Aug  8 07:59:57 2022:DART:KERNEL:ERROR:3:Slot 2:::1659959974:ThreadsServicesSupervisor: Service:NFSD Pool:NFSD_v4Daemons BLOCKED for 422 seconds: Server operations may be impacted .
Aug  8 07:59:57 2022:DART:KERNEL:ERROR:3:Slot 2:::1659959974:ThreadsServicesSupervisor: Service:NFSD Pool:NFSD_Exec BLOCKED for 400 seconds: Server operations may be impacted .

원인

  • There is an issue with the code in NFSv4_ClientList::Clean().
  • Upgrading to Cumulative Epack 5978.711.711_9699 or 9734 will upgrade eNAS version to 8.1.15.401 and introduce exposure if a filesystem is mounted with NFSv4.

해결

  • Customers running eNAS version 8.1.15.401 (Released in Cumulative Epacks 5978.711.711_9699 and 9734) and have NFSv4 mounted filesystems the recommendation is to remount the filesystem with NFSv3.
  • Customers running eNAS version 8.1.15.401 should submit an Epack request, requesting eNAS version 8.1.15.402.

해당 제품

PowerMax, Symmetrix, VMAX
문서 속성
문서 번호: 000202531
문서 유형: Solution
마지막 수정 시간: 14 12월 2022
버전:  8
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.