Dell Unity: Windows host using native MPIO unable to see LUNs on depopulated Unity XT 380 (Dell Correctable)
요약: Windows hosts using native MPIO are unable to see LUNs on a Unity XT 380/380F with depopulated service processors. This occurs when using the last two ports of the IOModule (port 2 or 3). Or when using the two CNA ports (4 or 5) without an IOModule installed. ...
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
- Windows hosts using native MPIO are unable to see LUNs
- Unity OE 5.2.x
- Unity XT 380 or 380F with depopulated (no onboard Ethernet ports) service processors (SPs)
- Using the last two ports of the IOModule (port 2 or 3) or using the two CNA ports (4 or 5) without an IOModule installed.
- The issue happens on both ISCSI connected and FC connected hosts.
- The issue happens with direct connect hosts and hosts connected through a switch.
- Windows VM with MPIO enabled shows two disks in Disk Management instead of having two connections seen as one disk.
원인
The Unity XT 380/380F running OE 5.2.x supports the new depopulated storage processors with the onboard Ethernet ports removed.
Windows hosts using native MPIO are unable to see LUNs on a Unity XT 380/380F with depopulated service processors. This occurs when using the last two ports of the IOModule (port 2 or 3). Or when using the two CNA ports (4 or 5) without an IOModule installed.
Windows hosts using native MPIO are unable to see LUNs on a Unity XT 380/380F with depopulated service processors. This occurs when using the last two ports of the IOModule (port 2 or 3). Or when using the two CNA ports (4 or 5) without an IOModule installed.
해결
Fix:
Workaround:
- This issue is fixed in Unity OS: 5.3.1.0.5.008
- Hotfixes are also available for Unity OE version 5.2. Contact Dell Technical Support or your Authorized Service Provider and quote this Dell Knowledge Base article ID to obtain those fixes.
Workaround:
- If an IOModule is installed, use CNA ports 4 & 5 and IOModule ports 0 & 1.
- Use PowerPath instead of Windows native MPIO.
- If there is no IOModule installed, CNA ports 4 and 5 do not work for Windows hosts using native MPIO.
해당 제품
Dell EMC Unity XT 380, Dell EMC Unity XT 380F문서 속성
문서 번호: 000212923
문서 유형: Solution
마지막 수정 시간: 25 7월 2025
버전: 11
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.