DSS7500: Doble falla y cómo forzar un disco en línea
요약: En este artículo, se aborda una DSS7500 falla doble y cómo forzar un disco en línea.
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
Configuración DSS7500:
- Tarjeta RAID SI9361-8i
- Se reemplazó el disco28
- El hot spare de Disk40 se está recreando
- Disk22 está offline
- La reconstrucción de Disk40 falló debido a un error del controlador de origen, hay dos discos duros fallidos y el VD falló
- Comprobación remota de disk22 HD offline, disk28 HD unconfigured en buen estado (faltante)
- El registro de la tarjeta RAID comprueba que VD0 se degrada cuando disk22 está offline y VD0 falló
Figura 1: Información de la controladora RAID
1034450: 23-10-28,08:06:02 BG Work:CopyBack progress on PD b4(e0x64/s32) is 99.25%(116579s) 1034451: 23-10-28,08:53:56 Info:CopyBack complete on PD b4(e0x64/s32) from PD ba(e0x64/s40) 1034452: 23-10-28,08:53:57 Info:State change on PD b4(e0x64/s32) from COPYBACK(20) to ONLINE(18) 1034453: 23-10-28,08:53:57 Info:Global Hot Spare created on PD ba(e0x64/s40) (global,rev) 1034454: 23-10-28,08:53:57 Info:State change on PD ba(e0x64/s40) from ONLINE(18) to HOT SPARE(2) 1034459: 23-10-31,15:05:18 Info:State change on PD a0(e0x65/s28) from ONLINE(18) to OFFLINE(10) 1034460: 23-10-31,15:05:18 Info:State change on VD 00/0 from OPTIMAL(3) to DEGRADED(2) 1034461: 23-10-31,15:05:18 CRITICAL:VD 00/0 is now DEGRADED. 1034475: 23-10-31,15:15:02 Info:Inserted: PD a0(e0x65/s28) 1034476: 23-10-31,15:15:02 Info:Inserted: PD a0(e0x65/s28) Info: enclPd=65, scsiType=0, portMap=00, sasAddr=5f01faf0fd32821c,0000000000000000 1034477: 23-10-31,15:15:02 Info:PD a0(e0x65/s28) Inquiry info: Info- ATA TOSHIBA MG07ACA1 T0A0CFF9SG 11 TB 1034478: 23-10-31,15:15:02 Info:State change on PD a0(e0x65/s28) from UNCONFIGURED_BAD(1) to UNCONFIGURED_GOOD(0) 1034481: 23-10-31,16:29:22 BG Work:Rebuild progress on PD ba(e0x64/s40) is 0.99%(5040s) … 1034534: 23-11-01,21:31:58 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 88 00 00 00 00 01 6e 67 88 98 00 00 00 08 00 00, Sense: 72 03 11 00 00 00 00 0C 00 0A 80 00 00 00 00 01 6E 67 88 98 1034585: 23-11-02,07:27:28 BG Work:Rebuild progress on PD ba(e0x64/s40) is 82.17%(145326s) 1034586: 23-11-02,07:48:59 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 88 00 00 00 00 03 c6 b3 20 00 00 00 02 00 00 00, Sense: 72 03 11 00 00 00 00 0C 00 0A 80 00 00 00 00 03 C6 B3 22 60 1034587: 23-11-02,07:48:59 Info:Error on PD 98(e0x65/s22) (Error 02) 1034588: 23-11-02,07:48:59 Info:State change on PD 98(e0x65/s22) from ONLINE(18) to SHIELD(90) 1034589: 23-11-02,07:48:59 Info:State change on VD 00/0 from DEGRADED(2) to OFFLINE(0) 1034590: 23-11-02,07:48:59 FATAL:Controller cache pinned for missing or offline VD 00/0 1034591: 23-11-02,07:48:59 FATAL:VD 00/0 is now OFFLINE 1034592: 23-11-02,07:48:59 Info:Error on PD 98(e0x65/s22) (Error 02) 1034593: 23-11-02,07:48:59 CRITICAL:Rebuild failed on PD by(e0x64/s40) due to source drive error 1034594: 23-11-02,07:48:59 Info:State change on PD ba(e0x64/s40) from REBUILD(14) to HOT SPARE(2) 1034597: 23-11-02,07:49:02 WARNING:PD 98(e0x65/s22) Path 5f01faf0fd328216 reset (Type 03) 1034598: 23-11-02,07:49:04 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 28 00 00 00 00 00 00 00 04 00, Sense: 70 00 06 00 00 00 00 0A 00 00 00 00 29 00 00 00 00 00 1034599: 23-11-02,07:49:04 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 00 00 00 00 00 00, Sense: 70 00 02 00 00 00 00 0A 00 00 00 00 04 02 00 00 00 00 1034601: 23-11-02,07:55:14 Info:Diagnostics passed for PD 98(e0x65/s22) 1034602: 23-11-02,07:55:14 Info:State change on PD 98(e0x65/s22) from SHIELD(90) to OFFLINE(10)
원인
Consulte a continuación
해결
- Intente poner en línea el último disco fuera de línea. Si el disco se pone en línea, el disco virtual puede recuperarse al estado degradado.
- En este caso, el disk22 en línea en la controladora RAID Utilidad de configuración de la infraestructura de interfaz humana (HII) AVAGO MegaRAID 9361-8i A continuación, se indican los pasos:
- Reinicie el servidor. Mientras el sistema se está iniciando, presione<F2>para ingresar a System Setup.
- Haga clic en Configuración del dispositivo para acceder al menú de administración de la controladora AVAGO MegaRAID 9361-8i. Utilice las teclas de flecha o el mouse para moverse.
Figura 2: Estado de RAID 50 offline
Figura 3: Puerto de unidad 0: disco duro 3:01:28 no configurado en buen estado
Figura 4: Puerto de unidad 0: 3:01:28 faltante
Figura 5: Puerto de unidad 0: 3:01:22 offline
Figura 6: Puerto de unidad 0: 3:01:22 offline
- Seleccione "Drive Port 0 - 3:01:22 hard drive" Operación>: >coloque la unidad en línea > Confirme que la operación sea correcta.
Figura 7: Coloque la unidad en línea
- Compruebe que el estado de RAID 50 se recupere a degradado.
Figura 8: Estado de RAID 50 degradado.
- Desde el software de administración AVAGO MegaRAID 9361-8i de la controladora RAID, compruebe que disk22 esté en línea y que disk40 se esté reconstruyendo.
Figura 9: Disk22 está en línea y disk40 se está reconstruyendo.
- Compruebe la información de la ranura del disco si debe reemplazar un disco.
Figura 10: Información de la ranura del disco
해당 제품
DSS 7500문서 속성
문서 번호: 000219727
문서 유형: Solution
마지막 수정 시간: 14 4월 2025
버전: 4
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.