DSS7500:双重故障以及如何强制联机磁盘
요약: 本文介绍了DSS7500双重故障以及如何强制使用联机磁盘。
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
DSS7500配置:
- SI9361-8i RAID 卡
- 已更换磁盘 28
- Disk40 热备盘正在重建
- Disk22 处于离线状态
- 由于源驱动程序错误,Disk40 重建失败,有两个硬盘出现故障,并且 VD 出现故障
- 远程检查 disk22 HD 脱机,disk28 HD 未配置完好(缺失)
- 当 disk22 离线且 VD0 发生故障时,RAID 卡日志检查 VD0 是否降级
图 1:RAID 控制器信息
1034450: 23-10-28,08:06:02 BG Work:CopyBack progress on PD b4(e0x64/s32) is 99.25%(116579s) 1034451: 23-10-28,08:53:56 Info:CopyBack complete on PD b4(e0x64/s32) from PD ba(e0x64/s40) 1034452: 23-10-28,08:53:57 Info:State change on PD b4(e0x64/s32) from COPYBACK(20) to ONLINE(18) 1034453: 23-10-28,08:53:57 Info:Global Hot Spare created on PD ba(e0x64/s40) (global,rev) 1034454: 23-10-28,08:53:57 Info:State change on PD ba(e0x64/s40) from ONLINE(18) to HOT SPARE(2) 1034459: 23-10-31,15:05:18 Info:State change on PD a0(e0x65/s28) from ONLINE(18) to OFFLINE(10) 1034460: 23-10-31,15:05:18 Info:State change on VD 00/0 from OPTIMAL(3) to DEGRADED(2) 1034461: 23-10-31,15:05:18 CRITICAL:VD 00/0 is now DEGRADED. 1034475: 23-10-31,15:15:02 Info:Inserted: PD a0(e0x65/s28) 1034476: 23-10-31,15:15:02 Info:Inserted: PD a0(e0x65/s28) Info: enclPd=65, scsiType=0, portMap=00, sasAddr=5f01faf0fd32821c,0000000000000000 1034477: 23-10-31,15:15:02 Info:PD a0(e0x65/s28) Inquiry info: Info- ATA TOSHIBA MG07ACA1 T0A0CFF9SG 11 TB 1034478: 23-10-31,15:15:02 Info:State change on PD a0(e0x65/s28) from UNCONFIGURED_BAD(1) to UNCONFIGURED_GOOD(0) 1034481: 23-10-31,16:29:22 BG Work:Rebuild progress on PD ba(e0x64/s40) is 0.99%(5040s) … 1034534: 23-11-01,21:31:58 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 88 00 00 00 00 01 6e 67 88 98 00 00 00 08 00 00, Sense: 72 03 11 00 00 00 00 0C 00 0A 80 00 00 00 00 01 6E 67 88 98 1034585: 23-11-02,07:27:28 BG Work:Rebuild progress on PD ba(e0x64/s40) is 82.17%(145326s) 1034586: 23-11-02,07:48:59 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 88 00 00 00 00 03 c6 b3 20 00 00 00 02 00 00 00, Sense: 72 03 11 00 00 00 00 0C 00 0A 80 00 00 00 00 03 C6 B3 22 60 1034587: 23-11-02,07:48:59 Info:Error on PD 98(e0x65/s22) (Error 02) 1034588: 23-11-02,07:48:59 Info:State change on PD 98(e0x65/s22) from ONLINE(18) to SHIELD(90) 1034589: 23-11-02,07:48:59 Info:State change on VD 00/0 from DEGRADED(2) to OFFLINE(0) 1034590: 23-11-02,07:48:59 FATAL:Controller cache pinned for missing or offline VD 00/0 1034591: 23-11-02,07:48:59 FATAL:VD 00/0 is now OFFLINE 1034592: 23-11-02,07:48:59 Info:Error on PD 98(e0x65/s22) (Error 02) 1034593: 23-11-02,07:48:59 CRITICAL:Rebuild failed on PD by(e0x64/s40) due to source drive error 1034594: 23-11-02,07:48:59 Info:State change on PD ba(e0x64/s40) from REBUILD(14) to HOT SPARE(2) 1034597: 23-11-02,07:49:02 WARNING:PD 98(e0x65/s22) Path 5f01faf0fd328216 reset (Type 03) 1034598: 23-11-02,07:49:04 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 28 00 00 00 00 00 00 00 04 00, Sense: 70 00 06 00 00 00 00 0A 00 00 00 00 29 00 00 00 00 00 1034599: 23-11-02,07:49:04 Info:Unexpected sense: PD 98(e0x65/s22) Path 5f01faf0fd328216, CDB: 00 00 00 00 00 00, Sense: 70 00 02 00 00 00 00 0A 00 00 00 00 04 02 00 00 00 00 1034601: 23-11-02,07:55:14 Info:Diagnostics passed for PD 98(e0x65/s22) 1034602: 23-11-02,07:55:14 Info:State change on PD 98(e0x65/s22) from SHIELD(90) to OFFLINE(10)
원인
见下文
해결
- 尝试强制将最后一个离线磁盘联机。如果磁盘联机,虚拟磁盘可以恢复到降级状态。
- 在这种情况下,在线 raid 控制器中的 disk22 AVAGO MegaRAID 9361-8i 人机接口基础架构 (HII) 配置实用程序 以下是步骤:
- 重新启动服务器。当系统处于启动状态时,按<F2>键进入 系统设置程序。
- 单击设备设置以访问控制器 AVAGO MegaRAID 9361-8i 的管理菜单。使用箭头键或鼠标移动。
图 2:RAID 50 状态 离线
图 3:驱动器端口 0 - 3:01:28 硬盘未配置良好
图 4:驱动器端口 0 - 缺少 3:01:28
图 5:驱动器端口 0 - 3:01:22 脱机
图 6:驱动器端口 0 - 3:01:22 脱机
- 选择“Drive Port 0 - 3:01:22 hard drive”>操作 将驱动器置于联机>状态 确认操作 >正常。
图 7:将驱动器置于联机状态
- 检查 RAID 50 状态是否恢复为 Degraded。
图 8:RAID 50 状态为降级。
- 在 RAID 控制器 AVAGO MegaRAID 9361-8i 管理软件中,检查 disk22 是否联机并且 disk40 正在重建。
图 9:Disk22 处于联机状态,并且 disk40 正在重建。
- 如果必须更换磁盘,请检查磁盘插槽信息。
图 10:磁盘插槽信息