PowerFlex: How to install SDC on Debian-based server (Debian, Ubuntu, Proxmox)

요약: The following procedure explains how to manually install an external SDC on a Debian-based server. The steps in the procedure below are relevant for Debian/Ubuntu operating systems, including Proxmox Virtual Environment. ...

이 문서는 다음에 적용됩니다. 이 문서는 다음에 적용되지 않습니다. 이 문서는 특정 제품과 관련이 없습니다. 모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.

지침

Retrieve SDC software

  1. Get SDC drivers for manual installation from the Dell Support Site
  2. From "Drivers & Downloads" section, search for "SDC Driver" as a Keyword.
  3. Download the "PowerFlex_*_SDCs_for_manual_install.zip" file matching the PowerFlex version intended to install.
    (SDC is backwards and forwards compatible with the PowerFlex system version. - see Release Notes)


SDC Drivers download

Extract Debian-based package (.deb)

PowerFlex component packages are delivered as .tar files for Debian-based operating systems. Before installation, the .deb package must be extracted using provided siob_extract utility:

  1. Extract SDC .zip file for your specific OS Release (from "PowerFlex_*_SDCs_for_manual_install.zip" archive)
  2. Check integrity (md5 or sha256) and inflate the SDC .zip file
  3. Uncompress "EMC-ScaleIO-sdc-*" .tar file
  4. Extract .deb package using siob_extract utility
# Extract SDC for Debian 12 (bookworm) / Proxmox VE 8.x
unzip PowerFlex_*_SDCs_for_manual_install.zip "*Debian12_SDC.*"

# Check integrity & inflate zip file
cd PowerFlex_*_SDCs_for_manual_install/
sha256sum PowerFlex_*_Debian12_SDC.zip
cat PowerFlex_*_Debian12_SDC.sha256
unzip PowerFlex_*_Debian12_SDC.zip

# Extract .deb package (using `siob_extract` utility)
cd PowerFlex_*_Debian12_SDC/
tar -xvf EMC-ScaleIO-sdc-*.Debian12.x86_64.tar
chmod +x siob_extract
./siob_extract EMC-ScaleIO-sdc-*.Debian12.x86_64.siob
ls EMC-ScaleIO-sdc-*.Debian12.x86_64.deb

For other OS Release, use: "*Debian13_SDC*", "*Ubuntu24.04_SDC*",....

Install SDC on the server and connect it to PowerFlex

  1. Collect MDM virtual IP addresses of the PowerFlex system (or all MDM managers IPs)
  2. Install SDC package
  3. Verify that the driver is loaded
MDM_IP="<MDM_IP1>,<MDM_IP2>,..." dpkg -i EMC-ScaleIO-sdc-*.deb
systemctl status scini.service

If scini.service fails to start, the "scini" driver is maybe not compatible with your kernel release. In this case, see how to configure driver_sync or on-demand compilation. Also using Secure Boot on SDC has some restrictions and requires additional steps.

Refer to documentation for recommended post deployment tasks or to map volumes to SDC.

해당 제품

PowerFlex rack, PowerFlex Appliance, PowerFlex custom node, ScaleIO, PowerFlex Software
문서 속성
문서 번호: 000462918
문서 유형: How To
마지막 수정 시간: 10 5월 2026
버전:  2
다른 Dell 사용자에게 질문에 대한 답변 찾기
지원 서비스
디바이스에 지원 서비스가 적용되는지 확인하십시오.