PowerFlex: How to Reboot a PowerFlex Node
요약: This article explains how to reboot different node types for PowerFlex system
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
지침
Note: Service Mode can be used instead of Maintenance Mode, which will put each node into the proper maintenance mode, meaning SDS node from PFMP and SDC from vCenter
MDM role switching is Not part of the Service Mode and must be done separately
Storage Only (SO) Nodes - SDSs
- Make sure the SDS is not a Primary MDM
- If SDS is Primary MDM , switch node role to be secondary MDM See PowerFlex 4.X: How to Switch MDM Ownership Using Command Line
- Only if the SDS is not Primary MDM , place node into IMM\PMM from PowerFlex Manager then reboot the node from iDRAC See Dell PowerFlex Appliance Administration Guide
Compute Only (CO) Nodes - SDCs
- Put the CO node into maintenance mode from vCenter and then reboot the node from iDRAC See Place an ESXi Host in Maintenance Mode in the VMware Host Client (External Link)
Hyperconverged Node (HCI) - SDS and SDC
- Put the node into maintenance mode from PowerFlex Manager- follow the same steps for SDS above
- Put the node into maintenance mode from vCenter - follow the same steps for SDC above
Management Node (MVM)
- See section Power off the PowerFlex management cluster (ESXi) in article PowerFlex: How to Power On\Off a Powerflex Appliance
Storage Data Replicator (SDR)
- Put SDR in MM and reboot from idrac See Dell PowerFlex 4.5.x and PowerFlex Manager 4.6.x Administration Guide