BigSwitch ZTD does not complete when using OS10 as p-network switch.

Samenvatting: The DellEMC OS10 based switch as the p-network switch for a BigSwitch Fabric. The BCF or BMF switches may not fully boot and connect to the controller in a switchlight operating system. The boot stops at the ZTD discovery. ...

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

 

The controller and switches can ping each other IPv6 link local address. However, the process still does not fully complete. This can occur when the IPv6 packet crosses between switches such as the topology below. 

P-Switch-Topology


 

 

 

 

Oorzaak

The MLD snooping will not forward the ipv6 ND packets across the port-channel between switches. 

Oplossing

To resolve this issue the following commands globally on both switches:

OS10(config)# no ip igmp snooping enable

OS10(config)# no ipv6 mld snooping enable

Dell EMC OS10 has IGMP snooping and IPv6 MLD snooping enabled by default. This can result in the IPv6 discovery frames from Switchlight to the controller to be intercepted between switches.