Isilon:重新映像时发生“找不到磁盘提供程序”错误

Samenvatting: 当重建映像程序找不到引导程序提供程序时,可能会发生找不到磁盘提供程序错误。

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

重建映像过程中出现错误消息“Cannot find disk provider”(找不到磁盘提供程序)。

Cannot find disk provider
Traceback (most recent call last):
  File "/root/bin/flashdisk_reimage.py", line 2375, in 
    sys.exit(main(getargs()))
  File "/root/bin/flashdisk_reimage.py", line 2251, in main
    setup_psi(args)
  File "/root/bin/flashdisk_reimage.py", line 1703, in setup_psi
    setup_psi_backup_device(args)
  File "/root/bin/flashdisk_reimage.py", line 1763, in setup_psi_backup_device
    psi_backup_device.providers.init_short()
  File "/root/bin/flashdisk_reimage.py", line 1213, in init_short
    bootdisk.init_providers(wipe=False)
  File "/b/mnt/obj/b/mnt/src/amd64.amd64/isilon/lib/python/stage-3.8/usr/local/lib/python3.8/site-packages/isi/sys/bootdisk.py", line 729, in init_providers
  File "/b/mnt/obj/b/mnt/src/amd64.amd64/isilon/lib/python/stage-3.8/usr/local/lib/python3.8/site-packages/isi/sys/bootdisk.py", line 730, in 
IndexError: list index out of range

用于确认问题的命令是: isi_bootstrap_devices -b,这将生成以下输出:

isi-bsd# /usr/bin/isi_hwtools/isi_bootstrap_devices -b
name:
isi-bsd#

Oorzaak

导致此问题的原因是节点 A 底座的最高插槽编号中缺少磁盘。

Oplossing

要解决该问题,请按照这些步骤操作:

  • 将驱动器放入节点 A 底座的最高插槽编号。如果由于故障卸下了驱动器,请更换出现故障的驱动器,然后再继续。
  • 如果您的驱动器处于最高的 A 插槽编号中,请将该驱动器与底座中的另一个驱动器交换。重新拔插底座后,再次尝试重置映像过程。

 

注意: 如果您不确定或担心要进行这些更改,请联系戴尔支持或浏览其网站以获得进一步的帮助。
提醒:小心放置硬件,以避免任何损坏。

Getroffen producten

Isilon Gen6, PowerScale A310, PowerScale A3100, PowerScale H710, PowerScale H7100
Artikeleigenschappen
Artikelnummer: 000359362
Artikeltype: Solution
Laatst aangepast: 16 jul. 2026
Versie:  2
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.