Deployment KB: Unable to power on the VM on ESXi host in the CR Vault
Samenvatting: During VM restore inside the cyber vault, VM restore failed to power on.
Dit artikel is van toepassing op
Dit artikel is niet van toepassing op
Dit artikel is niet gebonden aan een specifiek product.
Niet alle productversies worden in dit artikel vermeld.
Symptomen
In the /var/log/vmware.log file, similar entries to the below are seen:
Note: The log excerpts are examples. Date, time, and environmental variables may vary depending on the environment.
Unable to create virtual scsi0:0.filters="esx_splitter",
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
Oorzaak
Production VM protected using RP4VM may cause issues after restore inside the vault.
This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.
This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.
Oplossing
To resolve this issue, follow the steps below:
- Connect to the ESXi host the virtual machine is on using SSH and root credentials
- Navigate to the virtual machines .vmx file using this command:
cd /vmfs/volumes/datastore/virtual_machine_folder/
- Open the .vmx file with a text editor: vi virtual_machine.vmx
- Add a # before any filters that contain scsi0:0.filters="esx_splitter"
- Save the changes and exit the text editor.
- Power on the virtual machine.
Getroffen producten
Avamar, Cyber Recovery Series, VMware ESXi 6.xProducten
VMware ESXi 6.5.X, VMware ESXi 6.7.X, VMware ESXi 7.xArtikeleigenschappen
Artikelnummer: 000183528
Artikeltype: Solution
Laatst aangepast: 11 aug. 2022