VNX: How to attach same CIFS interface as NFS to the same VDM
Samenvatting: It is only possible to attach the same CIFS Interface as NFS to the same VDM through CLI Commands.
Dit artikel is van toepassing op
Dit artikel is niet van toepassing op
Dit artikel is niet gebonden aan een specifiek product.
Niet alle productversies worden in dit artikel vermeld.
Instructies
Connect to the Control Station SSH.
In order to view the interfaces attached as CIFS or NFS , apply the below command:
$nas_server -i -v <VDM_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -i -v PROD_VDM
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs
interface=Prodspace :cifs nfs
The above example shows Interface Name "nl0123nas0002_390" is attached as CIFS only, and Interface Name "Prodspace" is attached as CIFS and NFS.
To attach the same CIFS interface as NFS apply the below command:
$nas_server - vdm <VDM_Name> -attach <Interface_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -vdm PROD_VDM -attach nl0123nas0002_390
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs nfs
interface=Prodspace :cifs nfs
In order to view the interfaces attached as CIFS or NFS , apply the below command:
$nas_server -i -v <VDM_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -i -v PROD_VDM
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs
interface=Prodspace :cifs nfs
The above example shows Interface Name "nl0123nas0002_390" is attached as CIFS only, and Interface Name "Prodspace" is attached as CIFS and NFS.
To attach the same CIFS interface as NFS apply the below command:
$nas_server - vdm <VDM_Name> -attach <Interface_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -vdm PROD_VDM -attach nl0123nas0002_390
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs nfs
interface=Prodspace :cifs nfs
Getroffen producten
VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5700Producten
VNX5800, VNX7500, VNX7600, VNX8000Artikeleigenschappen
Artikelnummer: 000192930
Artikeltype: How To
Laatst aangepast: 23 okt. 2025
Versie: 3
Vind antwoorden op uw vragen via andere Dell gebruikers
Support Services
Controleer of uw apparaat wordt gedekt door Support Services.