Solutions Enabler: Symclone establish fails when SRDF/A is running

Samenvatting: Could not perform the symclone incremental establish when R2 devices as source are in a consistent state.

Dit artikel is van toepassing op Dit artikel is niet van toepassing op Dit artikel is niet gebonden aan een specifiek product. Niet alle productversies worden in dit artikel vermeld.

Symptomen

When SRDF devices are set to Async mode, R2 devices would be in a consistent state, so symclone establish would be failed as shown below: 
 
symrdf -g test_dg que 
 
Device Group (DG) Name       : test_dg
DG's Type                    : ANY
DG's Symmetrix ID            : 000xxxxxxxxx    (Microcode Version: 5876)
Remote Symmetrix ID          : 000yyyyyyyyy    (Microcode Version: 5876)
RDF (RA) Group Number        :  57 (38)         
Target (R2) View                         Source (R1) View     FLAGS
---------------------------------    ------------------------ ----- ------------
               ST                 LI       ST
Standard        A                  N        A
Logical  Sym    T R1 Inv  R2 Inv   K Sym    T R1 Inv  R2 Inv        RDF Pair
Device   Dev    E Tracks  Tracks   S Dev    E Tracks  Tracks  MCES  STATE
--------------------------------- -- ------------------------ ----- ------------
SRC01693  01693 WD      0       0 RW 04C32 RW       0       0 AX.E  Consistent
SRC03AA3 03AA3 WD       0       0 RW 02FCB RW       0       0 AX.E  Consistent 
Total             ------- -------             ------- -------
  Track(s)              0       0                   0       0
  MB(s)               0.0     0.0                 0.0     0.0 
Legend for FLAGS: 
(M)ode of Operation : A = Async, S = Sync, E = Semi-sync, D = Adaptive Copy Disk Mode
                    : W = Adaptive Copy WP Mode, M = Mixed, T = Active
(C)onsistency State : X = Enabled, . = Disabled, M = Mixed, - = N/A
(E)xempt            : X = Enabled, . = Disabled, M = Mixed, - = N/A
R1/R2 Device (S)ize : E = R1 EQ R2, 1 = R1 GT R2, 2 = R2 GT R1, - = N/A
symclone -g test_dg   establish -consistent -tgt 
 
Execute 'Incremental Establish' operation for device group
'test_dg' (y/[n]) ? y 
'Incremental Establish' operation execution is in progress for
device group 'test_dg'. Please wait... 

The request is not allowed for SRDF/A-capable devices in async mode

Oorzaak

When an R2 device in asynchronous mode is being used as a clone source, symclone establish command fails 
because an "establish" performs "recreate/activate" moments apart from each other. The precopy would never get a chance to be effective.

However -precopy or -copy can be used to maintain the SRDF/A consistency session while creating a clone copy.

Oplossing

To create a consistent clone copy, perform the "recreate/activate" commands separately a bit apart, instead of single establish command that includes both actions in tandem. 

Example below: 
 
symclone -g "test_dg" recreate -precopy -tgt
symclone -g "test_dg" activate -tgt -consistent

That would effectively work in place of the symclone establish.

Getroffen producten

PowerMax, Solutions Enabler Series, VMAX, VMAX All Flash, VMAX3 Series