PowerPath for AIX : PowerPath doesn't configure one of the path to a device, resulting in a duplicate PVID
Samenvatting: There can be different reasons for PowerPath not to pick-up a path and the most common reason is a "reserve_policy" mismatch between the hdisk and the pseudo device ... but insuch a case, the pseudo device remains "defined" since PowerPath doesn't know which reserve_policy needs to be applied to the pseudodevice. Here, both the hdiskpower and the leftover hdisk are available, resulting into a duplicate PVID issue (same PVID on the pseudo-device as the one on the leftover hdisk). ...
Dit artikel is van toepassing op
Dit artikel is niet van toepassing op
Dit artikel is niet gebonden aan een specifiek product.
Niet alle productversies worden in dit artikel vermeld.
Symptomen
DellEMC SW : PowerPath for AIX (any release)
Although there are 2 paths to a devices configured by the OS, PowerPath is missing one of the path. As a result, the PVID remains on the non configured hdisk and on the pseudo device.
e.g, # powermt display dev=1 Pseudo name=hdiskpower1 Symmetrix ID=00029780XXXX Logical device ID=00157 Device WWN=6000097000029780XXXX533030313537 state=alive; policy=SymmOpt; queued-IOs=0 ============================================================================== --------------- Host --------------- - Stor - -- I/O Path -- -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 5 fscsi6 hdisk233 FA 2d:08 active alive 0 0 # lspv ... hdisk1 00c94fa75919388d myvg1 ... hdiskpower1 00c94fa75919388d myvg1
Oorzaak
A process (which can't be identified) is holding the hdisk, preventing PowerPath from configuring the device.
Oplossing
Force the management of the leftover hdisk by PowerPath with a "powermt manage dev=hdiskXX". The "powermt manage" will return "Warning: management of the path hdiskXX will be configured upon reboot", proving that the disk is busy and this is the reason for the issue. Upon reboot, the disk will indeed be under PowerPath control..