PowerProtect:Transparent Snapshot Data Mover 虚拟机备份无法创建 LWD 快照
Resumo: vCenter 或 ESXi 升级到版本 8.0.2 后,Transparent Snapshot Data Mover (TSDM) 备份失败,但另一台主机仍使用 8.0.1。
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
Transparent Snapshot Data Mover (TSDM) 虚拟机备份失败,并显示以下任一错误:
此外,根据 VMware 互作性,vCenter Server 8.0U1 不支持 ESXi 8.0U2。有关最新结果,请参阅 VMware 产品互作性列表
。
图 1:VMware 的互作性结果
- 当 ESXi 升级到 8.0.2 但 vCenter 在 8.0.1 上时观察到。
ERROR ONE: The vCenter task failed: A specified parameter was not correct: sync id (500)
BackupVMSession 日志示例:
2023-10-05T13:28:32.712Z DEBUG: [b2cddd69bf2b2a3f;96fe2fd32rrr65e0] SDM Data Mover: SDM Delta Sync: Set VM Cleanup Descriptor. 2023-10-05T13:28:32.777Z ERROR: [b2c5gghhbf2b2a3f;96fe2fdttt7465e0] SDM Data Mover: SDM Delta Sync: The vCenter task failed: A specified parameter was not correct: sync Id 2023-10-05T13:28:32.777Z ERROR: [b2c50bfff2b2a3f;96fe2fd32f65e0] SDM Data Mover: SDM Delta Sync: The vCenter task for 'SDM Snapshot Sync deltaSync' completed with state 'error'.
- 当 vCenter 升级到 8.0.2 但 ESXi 在 8.0.1 上时观察到。
ERROR TWO: vCenter task 'task-72158' failed: VimFault: 'dp.vpx.fault.SnapshotInProgress.summary': DPD Snapshot in progress, TSDM snapshot UUID = '45kri245-34fb-4j58-adf6-e01f27dc3ggg' (500)”
BackupVMSession 日志示例:
2023-09-26T23:00:11.919Z DEBUG: [9391d79hhhb91652;924ec3b7edggf780] SDM Data Mover: Create LWD Snapshot: vCenter SOAP call 'DpSnapshot' was accepted. 2023-09-26T23:00:14.036Z ERROR: [939jjj99d1b91652;924ec3b7ggg1f780] SDM Data Mover: Create LWD Snapshot: vCenter task 'task-78140' failed: VimFault: 'dp.vpx.fault.DpsFault.summary': Unexpected PeResult 2023-09-26T23:00:14.036Z ERROR: [9391d799d1jjj652;924ec3b7ededf780] SDM Data Mover: Create LWD Snapshot: Unable to create LWD snapshot.
此外,根据 VMware 互作性,vCenter Server 8.0U1 不支持 ESXi 8.0U2。有关最新结果,请参阅 VMware 产品互作性列表
图 1:VMware 的互作性结果
Causa
PowerProtect Data Manager 工程部门针对 VMware 版本 8.0.1 <-> 8.0.2 中的 TSDM 执行了互作性测试。结果如下:
- ESXi 8.0.1 <-> Center 8.0.1 工作正常
- ESXi 8.0.2 <-> Center 8.0.1 失败,并显示错误“'SDM Snapshot Sync Full' 的 vCenter 任务已完成,状态为'error'。vCenter 任务失败:指定的参数不正确: sync Id (500)”
- ESXi 8.0.2 <-> Center 8.0.2 工作正常
- ESXi 8.0.1 <-> Center 8.0.2 失败,并显示错误“vCenter task 'task-72158' failed:VimFault:“dp.vpx.fault.SnapshotInProgress.summary”:DPD Snapshot in progress, TSDM snapshot UUID = '45e3b245-34fb-4d30-adf6-e01f27dc3aaa' (500)”
Resolução
由于 vCenter 和 ESXi 升级和版本不在 PowerProtect Data Manager 的范围内,因此如何继续由客户决定。
- 升级,以便 vCenter 和 ESXi 均在版本 8.0.2 上
- 降级,以便 vCenter 和 ESXi 均在版本 8.0.1 上
Mais informações
在将 vCenter 升级到 v8.0.3 以匹配 ESXi 版本后解决了 ESXi v8.0.3 和 vCenter v8.0.2
的相同问题。
Produtos afetados
PowerProtect Data ManagerProdutos
PowerProtect Data Manager SoftwarePropriedades do artigo
Número do artigo: 000218700
Tipo de artigo: Solution
Último modificado: 20 mar. 2025
Versão: 4
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.