PowerFlex: How to update device path and clear the SDS device errors using command line

Summary: Even after performing clean command, the SDS device error does not clear. Here are steps on how this can be fixed.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

This article explains how to clear device error for a device having mismatched device path and device original-path however in another scenario device may have mismatched device path and Original-path are still in Normal state 


  • Log in to the Primary MDM with admin login. use single quotes ' ' if password has special characters
    3.x 
    scli --login --username admin --password '<password>'
    
    4.x 
    scli --login --username admin --password '<password>' --management_system_ip <pfmp_ip>

     


  

 

 

  • Run the following command to list all SDSs details:
scli --query_all_sds

Example:

SDS ID: 2e400d3800000004 Name: LAB10_SDS3 State: Connected, Joined IP: XXX
SDS ID: 2e400d3700000003 Name: LAB10_SDS2 State: Connected, Joined IP: XXX
SDS ID: 2e400d3600000002 Name: LAB10_SDS4 State: Connected, Joined IP: XXX
SDS ID: 2e400d3500000001 Name: LAB10_SDS1 State: Connected, Joined IP: XXX
SDS ID: 2e400d3400000000 Name: LAB10_SDS5 State: Connected, Joined IP: XXX

 

  • Location the impacted SDS and note down the SDS name then run the following command
 scli --query_sds --sds_name <sds_name>

Example output:

4: Name: ScaleIO-3a5aeb6e  Path: /dev/sde  Original-path: /dev/sdu  ID: 2a71c74700030003
                Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error
13: Name: ScaleIO-3a5aeb77  Path: /dev/sdn  Original-path: /dev/sdl  ID: 2a71c7500003000c
                Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error

 

  • Location the impacted devices and note down the faulty device path 

In this example 2 devices are in error state, and unmatched device path and original-path

-Device path /dev/sde , Original-path /dev/sdu

-Device path /dev/sdn , Original-path /dev/sdl

  • Clear device error will run successfully but errors will not be cleared, for having 2 different paths 
scli --clear_sds_device_error --sds_id c948227100000004 --device_path  /dev/sdu
 Successfully cleared SDS device sds: with ID c948227100000004, /dev/sdu

 

 

Cause

SDS node may change the device path after node is rebooted 

 

Resolution

  • Update the original path to match the current path 
scli --update_device_original_path --sds_name <sds_name> --device_id <device_id>

Example:

scli --update_device_original_path --sds_name LAB10_SDS3 --device_id  2a71c74700030003

Note: To use device_id instead of using device_path as the device path can be different at some point but the above command will rectify the same. 

 

  • Clear device error 
Scli --clear_sds_device_error --sds_name <sds_name> --device_path <device path>

Example:

scli --clear_sds_device_error --sds_name LAB10_SDS3 --device_path /dev/sde
Scli --clear_sds_device_error --sds_name LAB10_SDS3 --device_path /dev/sdn

 

Produse afectate

PowerFlex rack, ScaleIO
Proprietăți articol
Article Number: 000027185
Article Type: Solution
Ultima modificare: 23 iun. 2026