PowerFlex: Background_Scanner_Compare_Error reset_scanner_error_counters

Summary: An SNMP trap is being continuously sent: MDM.Storage_Pool.Background_Scanner_Compare_Error

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

An SNMP trap is continuously sent: MDM.Storage_Pool.Background_Scanner_Compare_Error The PowerFlex log from the gateway server shows the following message streaming:

2017-11-22 16:43:45,341 [threadPoolTaskScheduler-1] INFO  c.e.s3g.scaleio.web.SNMP.TrapSender - Sending V2 Trap: 
TRAP[requestID=0, errorStatus=Success(0), errorIndex=0, VBS[1.3.6.1.2.1.1.3.0 = 2 days, 7:15:00.00; 
1.3.6.1.6.3.1.1.4.1.0 = 1.3.6.1.4.1.1139.101.1; 1.3.6.1.4.1.1139.101.1.1 = 5; 1.3.6.1.4.1.1139.101.1.2 = 
MDM.Storage_Pool.Background_Scanner_Compare_Error; 1.3.6.1.4.1.1139.101.1.3 = a7fc3e7d00000XXX; 
1.3.6.1.4.1.1139.101.1.4 = SIO02.04.0000007]] to target: CommunityTarget[address=x.x.x.x/x, version=1, 
timeout=5000, retries=2, community=public]
 

Cause

Check the events log from the Primary MDM for any device scanner errors: For example:

"ERROR            Background device scanner on device ID xxxxxxxxxxxx reported compare error (Device Path:
 /dev/sdd, SDS: XXX (ID XXXXXXXXXXXXX), Peer Device Path: /dev/sdd (ID XXXXXXXXXXXX), Peer SDS: XXXXX 
(ID XXXXXXXXX), Volume name: XXXXXXX, Volume offset: 1385641 MB)"

Resolution

The root cause is because the background device scanner counters are not zeroed -zeroed the counter to stop the messages.

 reset_scanner_error_counters


Reset background device scanner error counters for the specified storage pool or device. You can use this command to reset
counters for comparison errors, read errors, or both counter types.


Syntax
scli --reset_scanner_error_counters ((((--protection_domain_id  | -- protection_domain_name ) --storage_pool_name ) |--storage_pool_id ) | (--device_id  | ((--sds_id  | --sds_name  | --sds_ip  [--sds_port ]) (--device_name  | --device_path ))) ) 

[--reset_compare_errors]
[--reset_read_errors]


Parameters

--protection_domain_id 
Protection domain ID
--protection_domain_name 
Protection domain name
--storage_pool_name 

--sds_id 
SDS ID
--sds_name 
SDS name
--sds_ip 
SDS IP address
--sds_port 
Port assigned to the SDS
--device_id 
Device ID
--device_name 
Device name
--device_path 
SDS storage device path or file path
--storage_pool_id 
Storage pool ID
--reset_read_errors
Reset the read error counter.
--reset_compare_errors
Reset the compare error counter.
Note: If you use the storage_pool_id parameter in the command, you do not need to also specify the protection domain ID or name, and the storage pool name.
Note: If you use the device_id parameter in the command, you do not need to also supply the SDS ID or SDS name.

 

Example

scli --reset_scanner_error_counters --protection_domain_name pd120 --storage_pool_name sp120 --sds_name sds13 --reset_compare_errors 

 