PowerFlex: Background_Scanner_Compare_Error reset_scanner_error_counters
Summary: An SNMP trap is being continuously sent: MDM.Storage_Pool.Background_Scanner_Compare_Error
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
An SNMP trap is continuously sent: MDM.Storage_Pool.Background_Scanner_Compare_Error The PowerFlex log from the gateway server shows the following message streaming:
2017-11-22 16:43:45,341 [threadPoolTaskScheduler-1] INFO c.e.s3g.scaleio.web.SNMP.TrapSender - Sending V2 Trap: TRAP[requestID=0, errorStatus=Success(0), errorIndex=0, VBS[1.3.6.1.2.1.1.3.0 = 2 days, 7:15:00.00; 1.3.6.1.6.3.1.1.4.1.0 = 1.3.6.1.4.1.1139.101.1; 1.3.6.1.4.1.1139.101.1.1 = 5; 1.3.6.1.4.1.1139.101.1.2 = MDM.Storage_Pool.Background_Scanner_Compare_Error; 1.3.6.1.4.1.1139.101.1.3 = a7fc3e7d00000XXX; 1.3.6.1.4.1.1139.101.1.4 = SIO02.04.0000007]] to target: CommunityTarget[address=x.x.x.x/x, version=1, timeout=5000, retries=2, community=public]
Cause
Check the events log from the Primary MDM for any device scanner errors: For example:
"ERROR Background device scanner on device ID xxxxxxxxxxxx reported compare error (Device Path: /dev/sdd, SDS: XXX (ID XXXXXXXXXXXXX), Peer Device Path: /dev/sdd (ID XXXXXXXXXXXX), Peer SDS: XXXXX (ID XXXXXXXXX), Volume name: XXXXXXX, Volume offset: 1385641 MB)"
Resolution
The root cause is because the background device scanner counters are not zeroed -zeroed the counter to stop the messages.
reset_scanner_error_counters Reset background device scanner error counters for the specified storage pool or device. You can use this command to reset counters for comparison errors, read errors, or both counter types. Syntax scli --reset_scanner_error_counters ((((--protection_domain_id | -- protection_domain_name ) --storage_pool_name ) |--storage_pool_id ) | (--device_id | ((--sds_id | --sds_name | --sds_ip [--sds_port ]) (--device_name | --device_path ))) ) [--reset_compare_errors] [--reset_read_errors] Parameters --protection_domain_id Protection domain ID --protection_domain_name Protection domain name --storage_pool_name --sds_id SDS ID --sds_name SDS name --sds_ip SDS IP address --sds_port Port assigned to the SDS --device_id Device ID --device_name Device name --device_path SDS storage device path or file path --storage_pool_id Storage pool ID --reset_read_errors Reset the read error counter. --reset_compare_errors Reset the compare error counter.
Note: If you use the storage_pool_id parameter in the command, you do not need to also specify the protection domain ID or name, and the storage pool name.
Note: If you use the device_id parameter in the command, you do not need to also supply the SDS ID or SDS name.
Example
scli --reset_scanner_error_counters --protection_domain_name pd120 --storage_pool_name sp120 --sds_name sds13 --reset_compare_errors