Avamar:Data Domain 的後端容量報告無法執行:「功能未啟用」

Summary: Avamar 後端容量報告未針對 Data Domain 執行,報告「功能未啟用」。

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Data Domain (DD) 的後端容量報告不會執行,並報告「功能未啟用」(如下所示):

kA2j0000000RKTMCA4_3_0

 

Cause

Data Domain 的後端容量報告需要 compression physical-capacity-measurement Data Domain 作業系統 (DDOS) 5.7.x 和更高版本上的功能,要啟用。

Resolution

1.請確定 Data Domain 執行的是 DDOS 5.7.x 或更新版本。

2.確認 Data Domain 上已啟用實體容量測量功能:

compression physical-capacity-measurement status
 

若已啟用:

physical-capacity-measurement is enabled.
Initialization was not requested.
 

如果已停用:

physical-capacity-measurement is disabled.
 

3.如果已停用,請使用下列命令啟用:

compression physical-capacity-measurement enable
physical-capacity-measurement enabled.

Produse afectate

Avamar

Produse

Avamar
Proprietăți articol
Article Number: 000057575
Article Type: Solution
Ultima modificare: 21 oct. 2025
Version:  5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.