Unisphere configuration error: SMAS Database timeout cannot be started.
Summary: Unisphere for VMAX installation failed on a Linux server with an "SMAS Database timeout cannot be started" error.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
Unisphere for VMAX installation failed on a Linux host. The following error message appeared:
Deploying schema and create user for ROOT... Unisphere for VMAX Configuration Error. Installation will be aborted. Please check the Unisphere for VMAX documentation to fix this configuration issue. SMAS Database timeout cannot be started.
Cause
The postgres user login shell is incorrect.
Resolution
To address this issue, do the following:
- In the /etc/passwd file, change the postgres user login shell to /bin/bash.
- The login shell should not have "/usr/sbin/nologin" or "/bin/false".