NetWorker: v9.0 VMware-Jobs können nicht auf CloudBoost-Gerät geklont werden

Summary: Das Cloning von VMware vProxy-Savesets in CloudBoost schlägt fehl. Ungültige Saveset-IDs, keine Arbeitselemente, Fehler: Pool mit nicht unterstützten Nodes; Ursache: Node-Version 9.1.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

 

Das Cloning von VMware-Backup-Savesets (vProxy-Backup) auf ein CloudBoost-Gerät schlägt fehl.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

Überprüfung des Daemon-Protokolls zum Zeitpunkt <MM/TT/JJJJ HH:MM:SS MERIDIEM> des Fehlers findet die folgende Meldung:

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Cause

Bitte um Verbesserung. Bekanntes Problem: NW-I-404: NetWorker: Klonen von vProxy-Savesets auf eine CloudBoost-Appliance.

Resolution

Das Produktmanagement untersucht diesen Verbesserungswunsch. Die Anfrage ist noch in Bearbeitung. Wenden Sie sich an das Kundensupportcenter, um Unterstützung zu erhalten, und geben Sie diese Artikelnummer an.

PROBLEMUMGEHUNG: Konfigurieren Sie mit einer NetWorker 9.0.1- oder höheren Datenzone einen externen Storage Node. Weitere Informationen finden Sie im Abschnitt "NetWorker 9.1 CloudBoost 2.1 Integration Guide" im Abschnitt "NetWorker 9.1: Konfigurieren eines Geräts mithilfe eines externen Storage Node für CloudBoost".

Produse afectate

Cloud Backup & Protection, NetWorker
Proprietăți articol
Article Number: 000065416
Article Type: Solution
Ultima modificare: 04 dec. 2025
Version:  5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.