AppSync: Failed to perform vgchange operation on volume group DATA_VG

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

New Host Client Service Plan

The Service Plan event logs (CSV events) will show:
 
<Date> Mount copy,ed19fd04-0e9b-4008-be18-df4a94dac4d6,MILE_000002,<host-name>,Error occurred during the execution of service plan Oracle Test Plan
<Date> Mount copy,ed19fd04-0e9b-4008-be18-df4a94dac4d6,MILE_000005, <host-name>,Mount copy phase for oralab12 completed with errors
<Date> Mount copy,ed19fd04-0e9b-4008-be18-df4a94dac4d6,UNIX_000006, <host-name>,Unable to mount the filesystem /opt/oracle. The fsck operation failed.
<Date> Mount copy,ed19fd04-0e9b-4008-be18-df4a94dac4d6,UNIX_000026, <host-name>,Failed to perform vgchange operation on volume group DATA_VG.
See agent logs for more details. If the operation has timed out, retry after increasing the agent command timeout value for the host from Settings > Servers page in the AppSync UI.

 
Mount host plugin log:
 
host.py[2297]:mountFilesystem() vgimportclone exception :
WARNING: Not using device /dev/sdd1 for PV xxxxxx-Tbqr-vBWH-CTvL-lh6P-S0iW-xxxxxx.', '
WARNING: Not using device /dev/sde1 for PV xxxxxx-V5GN-w5nX-8wH8-DDdG-UKdF-xxxxxx.', '
WARNING: Not using device /dev/sde2 for PV xxxxxx-kt1Q-avdC-cwnU-YImd-1pOc-xxxxxx.', '
WARNING: PV xxxxxx-Tbqr-vBWH-CTvL-lh6P-S0iW-xxxxxx prefers device /dev/sdb1 because device is used by LV.', '
WARNING: PV xxxxxx-V5GN-w5nX-8wH8-DDdG-UKdF-xxxxxx prefers device /dev/sdc1 because device is used by LV.', '
WARNING: PV xxxxxx-kt1Q-avdC-cwnU-YImd-1pOc-xxxxxx prefers device /dev/sdc2 because device is used by LV.', '
Volume group "DATA_VG" not found', ' Cannot process volume group DATA_VG', '
WARNING: found device with duplicate /dev/sdb1', '
WARNING: found device with duplicate /dev/sdc1', '
WARNING: found device with duplicate /dev/sde2', '
WARNING: Disabling lvmetad cache which does not support duplicate PVs.', '
WARNING: Scan found duplicate PVs.', ' WARNING: Failed to scan devices.', ' WARNING: Update lvmetad with pvscan --cache.']

Cause

Unix partitioned devices are not supported with AppSync 4.0     
Check AppSync Support Matrix for latest supported Configuration notes On Linux/Unix Operating Systems

Resolution

This is listed in the AppSync Support Matrix:
 
AppSync does not support filesystems or ASM diskgroups on Linux operating system devices which are not full block devices (like /dev/sdc) or primary first partition (like /dev/sdc1)

Produse afectate

AppSync

Produse

AppSync
Proprietăți articol
Article Number: 000173539
Article Type: Solution
Ultima modificare: 05 mai 2026
Version:  4
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.