Data Domain:DD3300:更换磁盘后,磁盘警报仍然存在
Summary: 更换磁盘后,Data Domain 操作系统 (DDOS) 上的新磁盘信息不会更新,并且警报仍然存在。
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
提醒:DD3300运行经过修改的 Data Domain (DD) Virtual Edition (DDVE) 软件版本。
在 Data Domain 操作系统 (DDOS) 中:
1.新磁盘信息未更新:
# disk show hardware-detailed
Disk Slot Manufacturer/Model Firmware Serial No. Capacity Type State
(pci/idx)
---- --------- ------------------ -------- -------------- ---------- -------- --------
1.1 0 ST4000NM017A CSJ7 WJG12JG9 3.64 TiB SAS In Use
1.2 1 ST4000NM017A CSJ7 WJG18M5C 3.64 TiB SAS In Use
1.3 2 ST4000NM017A CSJ7 WJG12HZN 3.64 TiB SAS In Use
1.4 3 ST4000NM017A CSJ7 WJG18M6X 3.64 TiB SAS In Use
1.5 4 ST4000NM017A CSJ7 WJG19CGX 3.64 TiB SAS In Use
1.6 5 ST4000NM017A CSJ7 WJG17136 3.64 TiB SAS In Use
1.7 6 ST4000NM017A CSJ7 WJG19B57 3.64 TiB SAS In Use
1.8 7 ST4000NM017A CSJ7 WJG19DQ3 3.64 TiB SAS In Use
1.9 8 ST4000NM017A CSJ7 WJG17YCG 3.64 TiB SAS In Use
1.10 9 ST4000NM017A CSJ7 WJG18MK0 3.64 TiB SAS Unknown <<-- Old serial number
1.11 10 (absent) (absent) (absent) (absent) (absent) Absent
1.12 11 (absent) (absent) (absent) (absent) (absent) Absent
1.13 12 MZ7LH480HBHQ0D3 HG57 S5YJNE0N810008 447.13 GiB SATA-SSD Non-RAID
2.磁盘警报未清除:
Current Alerts
--------------
Id Post Time Severity Class Object Message
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
p0-24 Thu Dec 30 05:00:57 2021 CRITICAL HardwareFailure Enclosure=1:Disk=10:Cause=NA EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.
p0-25 Thu Dec 30 11:11:29 2021 WARNING HardwareFailure Enclosure=1:Disk=10:Cause=Predictive failure EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
There are 2 active alerts.
在 Integrated Dell Remote Access Controller (iDRAC) 内:
事件日志可能会显示磁盘更换操作的发现。但是,硬件更改不会传递给 DDVE。
iDRAC 事件:
Timestamp Record Message
2022-02-04 11:47:06 7 The watchdog timer expired.
2022-01-07 22:12:46 6 Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17 5 Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16 4 Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02 3 Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25 2 The watchdog timer expired.
在 ESXi 上:
而
PTAgent 侦听 iDRAC 不包含通信中断的证据:
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy Cause
iDRAC 不会刷新其存储信息。
对 iDRAC 的期望一直是它应该能够刷新其存储资源清册,并将最新和正确的磁盘信息提供给
PTAgent (在 ESXi 上)和 vulcanmon (在 DDOS 上),卸下或插入磁盘时。
有时 iDRAC 不刷新,必须手动重置 iDRAC。
Resolution
- 使用 UI 将 iDRAC 重置为联机状态。
- 按照 BMC 重置(也称为弱电释放)步骤执行冷重置(也称为“弱电释放”)。
- 检查并确认相关警报已清除,并且磁盘硬件按预期显示。
Produse afectate
Data Domain, DD3300 ApplianceProprietăți articol
Article Number: 000197080
Article Type: Solution
Ultima modificare: 18 iun. 2026
Version: 5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență