PowerEdge: STOR042 - Unsupported value for the specified attribute error while trying to create a Virtual Disk in IDRAC9

Summary: This article provides information about STOR042 error while creating a Virtual Disk.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Instructions

During the RAID array creation, we must add a name for the virtual disk: 
 

Example: RAID NAME
 

RAID creation


Once we confirm and "Add to pending" jobs: 
 

Add to pending jobs 
We get the following error:

Warning message 


 

Solution: 

In order to avoid the error, name the Virtual Disk and avoid using spaces between words. Example: 

"RAID_NAME" or "RAIDNAME" since spaces are not allowed. An additional option is leaving the name in blank, and autoname populates it once virtual disk is created. 

 

Example: 
 

RAID name



Create Virtual Disk 

Setup Virtual Disk 

Notes:
  • The autoname assigns a name as follows: Virtual Disk 0, Virtual Disk 1, Virtual Disk 2…Virtual Disk n." Autoname does allow spaces in its preconfigured naming. 
  • The error is similar to what is in Lifecycle controller. Go to F2 > Device settings > Dell PERC HXXXX Adapter configuration utility > Configuration management > Create Virtual Disk > Virtual disk name: 
 

Ok message 

Additional Information

Create a Virtual Disk Using iDRAC9

Duration: 00:00:53 (hh:mm:ss)
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

Produse afectate

PowerEdge RAID Controller H345, PowerEdge RAID Controller H745, PowerEdge RAID Controller H750 Adapter SAS, PowerEdge RAID Controller H755 Front SAS

Produse

PowerEdge R240, PowerEdge R250, PowerEdge R260, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515 , PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R670, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R770, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T140, PowerEdge T150, PowerEdge T160, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T40, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640 ...
Proprietăți articol
Article Number: 000199937
Article Type: How To
Ultima modificare: 16 dec. 2024
Version:  6
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.