Data Domain:檢測到 NVRAM 故障 |錯誤或故障狀況
Summary: NVRAM 及其電池備份單元 (BBU) 是 Data Domain 資料無損架構的關鍵元件。Data Domain 作業系統 (DDOS) 會監控這些元件。如果發生硬體故障,DDOS 會產生警示,必須立即解決才能維護系統完整性。
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
⚠️重要:請勿更換 NVRAM 卡或 BBU,除非 DDOS 已張貼故障警示。不建議主動更換。
適用於:
- 所有 Data Domain 系統
- 所有 DDOS 軟體版本
可能的警示:
NVRAM-00001: File system is disabled due to a problem with the NVRAM subsystemNVRAM-00002: Battery at low charge and not chargingNVRAM-00003: Excessive PCI or memory errorsNVRAM-00201: Hardware fault detected with NVRAM cardNVRAM-00202: Hardware fault detected with NVRAM remote batteryNVRAM-00204: Invalid condition detected with NVRAM battery
Cause
DDOS 持續監控 NVRAM 子系統。當它偵測到 NVRAM 卡或 BBU 故障時,會張貼警示。
此警示通常包含診斷詳細資料,但如果更換元件無法解決問題,則可能需要進一步調查。
Resolution
解決警示通常包括更換 NVRAM 卡或 BBU (若非整合式)。請遵循這些步驟:
- 產生支援套裝
- 向您的支援提供者提出服務要求。
實用的 CLI 命令:
-
# alerts show current # Check for active NVRAM or battery alerts # system show nvram # Review card errors and battery status # system show hardware # Confirm NVRAM card presence
⚠️注意:電池電量低於 100% 是正常現象。DDOS 會定期放電及充電,以管理電池健全狀況。
Additional Information
範例:
- 在這裡我們看到一個很好的NVRAM - 零“錯誤”和所有電池狀態都“正常”(即使電量為~96%)
sysadmin@itsaDD# system show nvram
NVRAM Cards:
Card Component Value
---- ------------------- -----------------------------------------------
1 Slot 10
Firmware version 2.0.4
Memory size 3.93 GiB
Errors 0 memory (0 uncorrectable), 0 PCI, 0 controller
Board temperature 35 C
CPU temperature 41 C
Number of batteries 4
Card model no 313-163-100A-02
Card serial no FLA011301nnnnn
Battery model no 313-164-100A-01
Battery serial no FLA021242nnnnn
---- ------------------- -----------------------------------------------
NVRAM Batteries:
Card Battery Status Charge Charging Time To Temperature Voltage
Status Full Charge
---- ------- ------ ------ -------- ----------- ----------- -------
1 1 ok 96 % enabled 0 mins 26 C 8.088 V
2 ok 95 % enabled 0 mins 27 C 8.082 V
3 ok 97 % enabled 0 mins 25 C 8.084 V
4 ok 95 % enabled 0 mins 26 C 8.072 V
---- ------- ------ ------ -------- ----------- ----------- -------
Produse afectate
Data Domain, PowerProtect Data Protection Appliance, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection HardwareProprietăți articol
Article Number: 000204334
Article Type: Solution
Ultima modificare: 31 oct. 2025
Version: 3
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.