Symptoms
Script GDDRPA23, in a STAR with AutoSwap configuration, was automatically submitted by the GDDR Event Manager (EVM) to resume ConGroup from DC2 to DC1 and the secondary site was not displayed in the banner correctly. An '*' was displayed instead of DC1.
09.35.23 JOB31056 +GDDO041I GDDR Confirmation ===> 799
799 **************************************************
799 * *
799 * Please Confirm Resume ConGroup *
799 * *
799 * *
799 * *
799 * Secondary DASD Site: * *
799 * *
799 **************************************************
09.35.23 JOB31056 +GDDO042A Please Confirm Resume ConGroup (Yes/No): The script was automatically submitted by the EVM.
01MAR 09:00:05 CONSOLE $HASP100 GDDRPA23 ON INTRDR GDDR-JOB FROM STCnnnnn GDDREVM The issue occurs if the script is submitted manually using the
F GDDRMAIN,SCRIPT,GDDRPA23command.
Cause
This is a software issue.
Resolution
Permanent Fix:
- For GDDR 6.0, PTF GD60020 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.
Produse afectate
Geographically Dispersed Disaster Restart (GDDR)Proprietăți articol
Article Number: 000209907
Article Type: Solution
Ultima modificare: 29 iul. 2025
Version: 4
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.