Cisco MDS:%PORT-4-TRANSCEIVER_DUPLICATE_WARNING

Summary: 客戶在交換 SFP 後收到重複的傳發器警告。

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

2024 Sep  8 16:30:30 switch01 %PORT-4-TRANSCEIVER_DUPLICATE_WARNING: Transceivers for Interfaces (fc4/25 fc4/27) contain duplicate Serial numbers (FNSxxxxxxxx)

2024 Sep 15 16:30:21 switch01 %PORT-4-TRANSCEIVER_DUPLICATE_WARNING: Transceivers for Interfaces (fc4/25 fc4/27) contain duplicate Serial numbers (FNSxxxxxxxx)

Cause

為防止發生此問題,請一次插入或刪除一個 SFP,至少等待兩個 s,然後再插入或刪除另一個 SFP。

Resolution

如果此問題已發生,請以不中斷的方式重新載入線卡以進行復原。

reload module x non-disruptive

 

Produse afectate

Connectrix, Connectrix MDS-Series Hardware

Produse

VxBlock and Vblock Systems, Connectrix MDS-9710-V2, Connectrix MDS-Series Firmware, Connectrix MDS-Series Firmware 9.X
Proprietăți articol
Article Number: 000239404
Article Type: Solution
Ultima modificare: 19 mai 2025
Version:  1
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.