Data Domain:DDOS 升級重新開機迴圈
Summary: DDOS 升級會在 BIOS 升級工作期間持續重新開機。iDRAC 工作佇列顯示韌體正在更新 BIOS。
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
伺服器會重新開機,並顯示為下載 BIOS Capsule 檔案並執行 BIOS 更新。伺服器重新開機後,BIOS 更新順序會在下列 POST 上重複執行。此模式無限期重複,直到手動干預。

Cause
當 iDRAC9 在更新暫存 BIOS 工作時記憶體不足,iDRAC SMA 精靈會在嘗試處理 BIOS 檔案傳輸時重新啟動。
Resolution
iDRAC9 韌體版本 6.00.30.00 會修正記憶體處理方式,以避免發生 BIOS 更新失敗的狀況。 因應措施:
清除並刪除目前的 iDRAC 工作,並重設 iDRAC。#racadm jobqueue delete -i JID_CLEARALL_FORCE (this is the only way to delete a job in running state).racadm>>racadm jobqueue delete -i JID_CLEARALL_FORCERAC1032: JID_CLEARALL_FORCE job(s) was cancelled by the user. #racadm racresetracadm>>racadm racresetRAC reset operation initiated successfully. It may take a few minutes for the RAC to come online again.
Produse afectate
DD OS, iDRAC9 - 5.xx SeriesProprietăți articol
Article Number: 000248899
Article Type: Solution
Ultima modificare: 01 mai 2026
Version: 4
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.