Data Domain:DDOS 升级重新启动循环

Summary: 在 BIOS 升级任务期间,DDOS 升级会持续重新启动。iDRAC 作业队列显示固件正在更新 BIOS。

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

服务器将重新启动,并出现以下载 BIOS 压缩文件并运行 BIOS 更新。服务器重新启动后,BIOS 更新顺序将在开机自检后重复。此模式会无限期重复,直到手动干预。 

 

 BIOS 更新  

BIOS 更新 2

 

 

Cause

当 iDRAC9 在更新暂存 BIOS 作业时内存不足时,iDRAC SMA 守护程序会在尝试处理 BIOS 文件传输时重新启动。

Resolution

iDRAC9 固件版本 6.00.30.00 更正了内存处理,以防止出现此暂存的 BIOS 更新失败情况。

解决 方案:
清除并删除当前 iDRAC 作业并重置 iDRAC。

#racadm jobqueue delete -i JID_CLEARALL_FORCE (this is the only way to delete a job in running state).

racadm>>racadm jobqueue delete -i JID_CLEARALL_FORCE
RAC1032: JID_CLEARALL_FORCE job(s) was cancelled by the user. #racadm racreset

racadm>>racadm racreset
RAC reset operation initiated successfully. It may take a few minutes for the RAC to come online again.