Data Domain: Changing Bond Type with LACP Switch configuration Disables Interfaces

Summary: On intel network cards changing virtual bond to another bonding type while switch is still LACP triggers a possible driver bonding issue and disables all interfaces on all cards.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Loss of connectivity on all interfaces 

kern.info logs show the following:
ice 0000:1f:00.0: Error clearing VSI prune list
ice 0000:af:00.2: Failed to remove RDMA switch rule
ice 0000:ae:00.2: ethXx: Attempt to be Primary, but incompatible state. 1

Cause

Changing a virtual bond through the DD UI or CLI from LACP to another type while switch side is configured for LACP disables all interfaces. 
The root cause is a known class of rare ice driver issue on intel network cards. 

Resolution

Undo the change by iDRAC and a reboot to restore connectivity.
If iDRAC is not available, then direct serial access is needed. 
Engineering PowerEdge and Intel team are working on a permanent fix.

Produse afectate

Data Domain
Proprietăți articol
Article Number: 000482096
Article Type: Solution
Ultima modificare: 30 iun. 2026
Version:  1
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.