MFE SCF: Remote Thin Pool Space Monitoring Fails to Issue Error Message When it Stops Monitoring

Сводка: Remote THIN (THN) Monitor does not provide an informational message when it stops working due to link drops. It also does not automatically start up again once the links are active again. ...

Данная статья применяется к Данная статья не применяется к Эта статья не привязана к какому-либо конкретному продукту. В этой статье указаны не все версии продуктов.

Симптомы

After a network outage, the snap jobs have stopped working. After the snap jobs are running again, the user noticed that the Thin Pool Space monitoring was not working on the remote system. There was no message notifying that the remote monitoring had stopped and not restarted.

Причина

This is due to a software issue.

Разрешение

Workaround:
Remote monitoring did not default to being active. The network outage stopped the THIN (THN) Monitoring on the remote frame. Since the user had THIN (THN) Remote Monitoring specified in their SCF INI parameter file, they ran the command:
SCF INI,REFRESH
They followed this command with the command:
THN,REFRESH
This action resulted in their THIN (THN) monitor becoming active again.

Resolution:
  • For Mainframe Enablers 8.4, PTF SF84110 and PTF SN84057 are available to address the issue. They are available to download from Dell Online Support.
  • For Mainframe Enablers 8.5, PTF SF85011 and PTF SN85008 are available to address the issue. They are available to download from Dell Online Support.
  • For Mainframe Enablers 10.0.0, the issue is addressed in the base product. It is available to download from Dell Online Support.