Data Domain: NVRAM Hardware Failure Alert | EVT‑NVRAM‑00201
Zhrnutie: This article describes the conditions that trigger the 'NVRAMHardwareFailure' alert on Data Domain systems and outlines the required resolution steps.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
A Critical alert is generated indicating an NVRAM hardware failure. When this alert is present:
- The NVRAM card is considered unusable or unreliable.
- The Data Domain file system cannot be accessed until the issue is corrected.
- System operation may be blocked or degraded.
Alert Details:
Alert ID: EVT‑NVRAM‑00201Severity: CriticalClass: hardwareFailureObject: Slot=%sMessage:
“A hardware fault was detected with an NVRAM card and it may need to be replaced.”
Applies to:
- All Data Domain systems
- For systems (DD9910,DD9410, DD6410, DD9910F) with Software Defined Persistent Memory (SDPM) See KB: Data Domain: How to Diagnose and Resolve SDPM | NVRAM Alerts
- SDPM-NVRAM errors also trigger the DDOS NVRAM-00201 Alert - analysis into the related iDRAC error code is required (part replacement may not be needed).
- For systems (DD9910,DD9410, DD6410, DD9910F) with Software Defined Persistent Memory (SDPM) See KB: Data Domain: How to Diagnose and Resolve SDPM | NVRAM Alerts
- All Software/DDOS versions
Príčina
The NVRAMHardwareFailure alert is triggered when the system detects a hardware condition that renders the NVRAM card unusable. These conditions fall into two categories:
- Configuration issues detected during system boot
- Hardware component failures detected during boot or normal operation
If multiple failures are detected simultaneously, the alert reports:
"Multiple NVRAM hardware failures."
Examples of conditions that may trigger this alert include (but are not limited to):
- NVRAM card not detected
- Unsupported or mixed NVRAM card types
- Incorrect number of NVRAM cards for the platform
- NVRAM card and DDR model mismatch
- Inability to retrieve NVRAM card or battery information
- Excessive correctable or uncorrectable NVRAM memory errors
- NVRAM device operating in read‑only mode
- Incorrect NVRAM memory size, PCIe link speed, or link width
- Critical voltage rail conditions affecting NVRAM components
Specific failure details are provided in the alert field:
Info: Cause=%s
Riešenie
- Run offline diagnostics or system healthcheck to confirm the NVRAM failure.
- Useful Commands:
# alerts show current# system show nvram# support healthcheck hardware | # system health check# system show hardware
- Useful Commands:
- Correct any placement or configuration issues if applicable.
- If the NVRAM is PCIe-based (All-in-one) - replace the NVRAM card if diagnostics confirm a hardware failure.
- SDPM-NVRAM requires additional analysis:
If assistance is required, contact your contracted support provider - Dell Tech Support
Dotknuté produkty
Data DomainProdukty
Data DomainVlastnosti článku
Číslo článku: 000011063
Typ článku: Solution
Dátum poslednej úpravy: 27 júl 2026
Verzia: 7
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.