Data Domain: Disk Unknown
Zhrnutie: This article explains the conditions under which a disk may report as "Unknown" on Data Domain systems and provides steps to identify and resolve the issue.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
- A disk appears with the state "Unknown" in the system.
- The issue may affect:
- A single disk in the system controller (head unit) or attached storage
- All disks in a newly attached enclosure
- A disk recently replaced due to failure
Príčina
A disk may report as "Unknown" due to one of the following reasons:
- A newly installed disk is not (yet) recognized by the system.
- A disk in the system is unreliable (for example, a failed disk reports an 'unknown' state).
- An entire enclosure has been added but not yet integrated into the RAID group.
- A single disk replacement has not been properly initialized.
Riešenie
Follow the steps below based on the scenario:
-
Verify Disk State
- Use the
disk show statecommand to identify the disk state. Refer to Data Domain: Disk State Descriptions for guidance
- Use the
-
Single Disk Reports "Unknown" (and is NOT a new replacement disk)
- Check active system alerts (
alerts show current) and disk state (disk show state)- If the disk is reported as failed, and is in an 'unknown' state - replace the 'unknown/failed' disk
- If the 'unknown' disk is a newly installed (replacement) disk, see Step 4.
- Check active system alerts (
-
All Disks in a New Enclosure Report "Unknown"
- This is expected behavior for a newly added shelf.
- Follow the relevant Shelf Hardware Guide to get the 'Unknown' disks added to storage capacity.
- A basic overview of the steps to add a new shelf: Obtain relevant licensing, add the storage to the required storage tier (active, cloud) and then expand the filesystem,
- This is expected behavior for a newly added shelf.
-
Single Disk Reports "Unknown" After Replacement
- Attempt a rescan of drives. Run command # disk rescan
- Verify status of drive from DD-CLI # disk show state
- If the disk has become 'In-use' and the alert has not cleared, manually clear the alert using DD-CLI
# alerts clear alert-id <alert-id> - If the disk remains 'unknown' - run the #
disk unfail <encl.disc>command to transition the disk to a spare state.
- If the disk has become 'In-use' and the alert has not cleared, manually clear the alert using DD-CLI
-
Need Additional Assistance
- If the issue remains unresolved:
- Contact your contracted support provider and raise a service request.
- If the issue remains unresolved:
Ďalšie informácie
Dotknuté produkty
Data DomainProdukty
Data DomainVlastnosti článku
Číslo článku: 000043258
Typ článku: Solution
Dátum poslednej úpravy: 28 okt 2025
Verzia: 4
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.