VNX Storage Processor reports event 71678001 ESP_ERROR_SPS_REMOVED
Zhrnutie: Event 71678001 reported for either a Standby Power Supply or a Battery Backup Unit.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
Standby Power Supply (SPS) failures can potentially cause Write Cache to become disabled.
The array reports event codes such as the following:
71678001 ESP_ERROR_SPS_REMOVED 71678001 BBUA has been Removed
Príčina
The event is for either the SPS or the Battery Backup Unit Assembly (BBUA), depending on the array type.
This event may also be reported as part of the SP boot sequence, which is not a fault if it is followed by events such as the following:
espkg 71670002 BBUA Inserted. espkg 71670003 BBUA State Changed (TestStarted to TestCompleted). espkg 71670003 BBUA State Changed (NotBatteryReady to BatteryReady). espkg 71670003 BBUA State Changed (Testing to BatteryReady).
Riešenie
SPcollects should be gathered and checked to see if the SPS or BBU is still faulted.
Determine if the SPS/BBU was intentionally removed or if there is some problem such as a loose cable or incorrectly inserted component.