Troubleshooting Wyse 3040 Thin Client Power LED Amber Error Code
Zhrnutie: Resolve the Wyse 3040 Thin Client power LED amber error code caused by external pressure on the chassis. Discover how this triggers a CMOS reset and steps to recover your device.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
Affected Products:
- Wyse 3040
Units experience a power LED display error code flash cycle of three amber LEDs, followed by one amber LED. LED error flash cycle repeats three times, followed by one long amber LED, and then continues to POST (turn on self-test).
Thin client display's the following error messages during POST:
Invalid configuration information - please run SETUP program. Time-of-day not set - please run SETUP program. Press F1 key to retry boot. Press F2 key for setup utility. Press F5 key to run onboard diagnostics.

Príčina
A manufacturing design is the cause of the issue, where WIFI antenna wires are routed on top of the CLEAR CMOS button on the motherboard.
Riešenie
To recover, press F1 to retry boot, and the error message goes away.
Dotknuté produkty
Wyse 3040 Thin ClientVlastnosti článku
Číslo článku: 000126115
Typ článku: Solution