Data Domain: Changing Bond Type with LACP Switch configuration Disables Interfaces
Zhrnutie: On intel network cards changing virtual bond to another bonding type while switch is still LACP triggers a possible driver bonding issue and disables all interfaces on all cards.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
Loss of connectivity on all interfaces
kern.info logs show the following:
ice 0000:1f:00.0: Error clearing VSI prune list
ice 0000:af:00.2: Failed to remove RDMA switch rule
ice 0000:ae:00.2: ethXx: Attempt to be Primary, but incompatible state. 1Príčina
Changing a virtual bond through the DD UI or CLI from LACP to another type while switch side is configured for LACP disables all interfaces.
The root cause is a known class of rare ice driver issue on intel network cards.
Riešenie
Undo the change by iDRAC and a reboot to restore connectivity.
If iDRAC is not available, then direct serial access is needed.
Engineering PowerEdge and Intel team are working on a permanent fix.
Dotknuté produkty
Data DomainVlastnosti článku
Číslo článku: 000482096
Typ článku: Solution
Dátum poslednej úpravy: 30 jún 2026
Verzia: 1
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.