ECS: Dial Home - Ref_ID: RepoDiskLevelGC - Symptom Code: 1337
Summary: This is a dial home detects if space reclamation is too slow.
Bu makale şunlar için geçerlidir:
Bu makale şunlar için geçerli değildir:
Bu makale, belirli bir ürüne bağlı değildir.
Bu makalede tüm ürün sürümleri tanımlanmamıştır.
Symptoms
An ECS has dialed home with the following alert.
<?xml version="1.0" encoding="UTF-8"?>
<ConnectHome SchemaVersion="1.0.8"
xsi:schemaLocation="/opt/connectemc/schema/ema_ConnectHome108.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<Event>
<SymptomCode>1337</SymptomCode>
<Category>Configuration</Category>
<Severity>Warning</Severity>
<Status>Unknown</Status>
<Component>Object</Component>
<ComponentID></ComponentID>
<SubComponent>REPO Disk GC</SubComponent>
<SubComponentID></SubComponentID>
<CallHome>true</CallHome>
<FirstTime>2019-01-29T17:08:22.642Z</FirstTime>
<LastTime>2019-01-29T17:08:22.642Z</LastTime>
<Count>0</Count>
<EventData><![CDATA[]]></EventData>
<Description><![CDATA[Capacity free-up throughput is too slow to catch up with user garbage collection. Please involve ECS engineering. [Ref_ID : RepoDiskLevelGC]]]></Description>
</Event>
</EventList>
</InternalData>
<ExternalFiles/>
</Node>
</ConnectHome>Cause
The Space Reclamation on user data is too slow. The bottleneck lies on chunk level reclamation. This alert is generated when:
1. More than 10 TB of full garbage is present.
2. The difference between the garbage detection rate and the garbage chunk reclaim rate is greater than 100 GB.
This can trigger as a false alert if a recent large deletion has been made. Follow the steps below to determine if so.
Resolution
- Connect to one of the nodes in the cluster over a putty session.
- Verify Current Sensor Status.
# svc_rest_cmd /vdc/sensor/status/RepoDiskLevelGC
Example:
# svc_rest_cmd /vdc/sensor/status/RepoDiskLevelGC
svc_rest_cmd 1.0.10
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<SensorStatusList>
<SensorId>RepoDiskLevelGC</SensorId>
<ListSensorStatus>
<SensorStatusRestRep>
<ContextId>Repo Disk Level GC</ContextId>
<CurrentState>OK</CurrentState>
<NodeId>47b32995-35fc-4593-8f3c-39c878fb10ad</NodeId>
<PreviousState>OK</PreviousState>
<Time>1551104230509</Time>
</SensorStatusRestRep>
</ListSensorStatus>
- Look for <CurrentState>, if it is set to OK, then error is not active and this is likely a false alert. Ignore the alert, but if it triggers again within the next week then open a service request with Technical Support.