Connectrix B-Series :SFP 的 Rx 電源值小於 200
摘要: SFP 的 Rx 電源值小於 200
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
-“errdump”中的以下消息正在交換機上流式傳輸。
Fabric OS: 7.2.1C1 版
Fabric OS: 7.2.1C1 版
"errdump" : 2016/03/08-09:48:19, [MAPS-1004], 50674, SLOT 7 | FID 128, INFO, , SFP 12/17, Condition=ALL_SFP(RXP<=200), Current Value:[RXP,193 uW], RuleName=MAPSRUL_P4_ALS_RXP_LE_200_NON, Dashboard Category=Port Health. switchshow: switchType: 62.3 Index Slot Port Address Media Speed State Proto ============================================================ 241 12 17 03f100 id 4G Online FC F-Port xx:xx:xx:xx:xx:xx:xx:xx porterrshow : frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err 241: 5.0m 989.4k 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 "sfpshow" : Slot 12/Port 17: ============= Identifier: 3 SFP Connector: 7 LC Transceiver: 540c402000000000 2,4,8_Gbps M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 85 (units 100 megabaud) Length 9u: 0 (units km) Length 9u: 0 (units 100 meters) Length 50u (OM2): 5 (units 10 meters) Length 50u (OM3): 0 (units 10 meters) Length 62.5u:3 (units 10 meters) Length Cu: 0 (units 1 meter) Vendor Name: BROCADE Vendor OUI: 00:05:1e Vendor PN: 57-1000117-01 Vendor Rev: A Wavelength: 850 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 0 BR Min: 0 Serial No: UAA312184041271 Date Code: 120509 DD Type: 0x68 Enh Options: 0xf0 Status/Ctrl: 0x0 Alarm flags[0,1] = 0x0, 0x0 Warn Flags[0,1] = 0x0, 0x0 Alarm Warn low high low high Temperature: 30 Centigrade -15 100 -10 95 Current: 6.832 mAmps 2.000 10.500 2.000 10.500 Voltage: 3319.9 mVolts 2800.0 3800.0 2970.0 3630.0 RX Power: -7.1 dBm (193.5uW) 0.0 uW 6550.0 uW 49.0 uW 1100.0 uW TX Power: -2.8 dBm (528.7 uW) 50.0 uW 800.0 uW 100.0 uW 700.0 uW State transitions: 1 Last poll time: 03-08-2016 CET Tue 09:43:51 fabriclog --show : Time Stamp Input and *Action S, P Sn,Pn Port Xid =================================================================================== Switch 0; Fri Mar 4 11:46:22 2016 CET (GMT+1:00) 11:46:22.608002 SCN Port Offline;g=0x3e A2,P0 A2,P0 241 NA 11:46:22.608009 *Removing all nodes from port A2,P0 A2,P0 241 NA 11:46:24.694172 SCN LR_PORT(0);g=0x3e A2,P0 A2,P0 241 NA 11:46:24.694184 SCN Port Online; g=0x3e,isolated=0 A2,P0 A2,P1 241 NA 11:46:24.694234 Port Elp engaged A2,P1 A2,P0 241 NA
原因
- MAPS 產生警示,因為它低於建議的 200uW 等級 (SFP 的接收功率低於應有的水準)。
解析度
請客戶判斷傳送 (連接裝置) SFP/HBA 的傳輸功率 (或要求 EMC 擷取,並與主機團隊確認)。
- 如果裝置的 TX 電源正常,則應更換交換器的 SFP。
- 如果設備的TX電源不正常,則應更換所連接設備的SFP。
受影響的產品
Connectrix, Connectrix B-Series文章屬性
文章編號: 000064661
文章類型: Solution
上次修改時間: 11 12月 2025
版本: 7
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。