Connectrix B-Series :SFP 的 Rx 電源值小於 200

摘要: SFP 的 Rx 電源值小於 200

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

-“errdump”中的以下消息正在交換機上流式傳輸。

Fabric OS:  7.2.1C1 版
 
"errdump" :

2016/03/08-09:48:19, [MAPS-1004], 50674, SLOT 7 | FID 128, INFO, , SFP 12/17, Condition=ALL_SFP(RXP<=200), Current Value:[RXP,193 uW], RuleName=MAPSRUL_P4_ALS_RXP_LE_200_NON, Dashboard Category=Port Health.

switchshow:
switchType:    62.3
Index Slot Port Address Media  Speed        State    Proto
============================================================
 241   12   17   03f100   id    4G       Online      FC  F-Port  xx:xx:xx:xx:xx:xx:xx:xx 

porterrshow        :
          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy    c3timeout    pcs
       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                   tx    rx     err
241:    5.0m 989.4k   0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0   

"sfpshow" :

Slot 12/Port 17:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 540c402000000000 2,4,8_Gbps M5,M6 sw Inter_dist
Encoding:    1    8B10B
Baud Rate:   85   (units 100 megabaud)
Length 9u:   0    (units km)
Length 9u:   0    (units 100 meters)
Length 50u (OM2):  5    (units 10 meters)
Length 50u (OM3):  0    (units 10 meters)
Length 62.5u:3    (units 10 meters)
Length Cu:   0    (units 1 meter)
Vendor Name: BROCADE         
Vendor OUI:  00:05:1e
Vendor PN:   57-1000117-01   
Vendor Rev:  A   
Wavelength:  850  (units nm)
Options:     001a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max:      0   
BR Min:      0   
Serial No:   UAA312184041271 
Date Code:   120509  
DD Type:     0x68
Enh Options: 0xf0
Status/Ctrl: 0x0
Alarm flags[0,1] = 0x0, 0x0
Warn Flags[0,1] = 0x0, 0x0
                                           Alarm                  Warn
                                    low         high       low         high
Temperature: 30      Centigrade      -15        100        -10         95
Current:     6.832   mAmps           2.000      10.500     2.000       10.500 
Voltage:     3319.9  mVolts          2800.0     3800.0     2970.0      3630.0 
RX Power:    -7.1    dBm (193.5uW)   0.0    uW  6550.0 uW  49.0   uW   1100.0 uW
TX Power:    -2.8    dBm (528.7 uW)  50.0   uW  800.0  uW  100.0  uW   700.0  uW

State transitions: 1
Last poll time: 03-08-2016 CET Tue 09:43:51

fabriclog --show       :
Time Stamp      Input and *Action                           S, P   Sn,Pn  Port  Xid 
===================================================================================
Switch 0; Fri Mar  4 11:46:22 2016 CET (GMT+1:00)
11:46:22.608002 SCN Port Offline;g=0x3e                     A2,P0  A2,P0  241   NA    
11:46:22.608009 *Removing all nodes from port               A2,P0  A2,P0  241   NA    
11:46:24.694172 SCN LR_PORT(0);g=0x3e                       A2,P0  A2,P0  241   NA    
11:46:24.694184 SCN Port Online; g=0x3e,isolated=0          A2,P0  A2,P1  241   NA    
11:46:24.694234 Port Elp engaged                            A2,P1  A2,P0  241   NA    

原因

- MAPS 產生警示,因為它低於建議的 200uW 等級 (SFP 的接收功率低於應有的水準)。

解析度

請客戶判斷傳送 (連接裝置) SFP/HBA 的傳輸功率 (或要求 EMC 擷取,並與主機團隊確認)。
  • 如果裝置的 TX 電源正常,則應更換交換器的 SFP。
  • 如果設備的TX電源不正常,則應更換所連接設備的SFP。 

受影響的產品

Connectrix, Connectrix B-Series
文章屬性
文章編號: 000064661
文章類型: Solution
上次修改時間: 11 12月 2025
版本:  7
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。