NMDA Sybase PIT recover fails with Incorrect time syntax in the time string used in the LOAD TRANSACTION UNTIL_TIME
摘要: NMDA Sybase PIT recover fails with Incorrect time syntax in time string.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
- NMDA Sybase PIT recover fails with Incorrect time syntax
Incorrect time syntax in time string '<mon dd, yyy hh:mm:ss:sss>' used in the LOAD TRANSACTION UNTIL_TIME statement. Correct format is month day, year hour:minute:seconds:milliseconds[am | pm].
- month is expressed in Portuguese instead of English
- The Sybase client's region is set to Brazil. The language is set to Portuguese/Brazil. The locale is set to English.
- Backups are succeeding
原因
Code defect. The issue occurred due to the date format.
解析度
The code was modified to align the date format with the expected date format. The code fix is in NMDA 19.9.0.4 (tentative Jan 18th 2024).