Data Domain: Troubleshooting a "Net Set Up Flag Failure" Error

摘要: This article discusses a "net set up flag failure when an interface is enabled.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

When an interface is enabled, the error net set up flag failure may appear:

sysadmin@dd01-p1(active:1)# net enable veth2
net set up flag failure for: eth8a
sysadmin@dd01-p1(active:1)#

sysadmin@dd01-p1(active:1)# net enable ethMa 
net set up flag failure for: ethMa
sysadmin@dd01-p1(active:1)#

原因

There can be multiple causes of this error:

  • The network card driver must be unloaded and reloaded.
  • A memory allocation issue occurs in one of the file system layers.
  • The network card may be defective.
  • Older Data Domain models using Cyber Recovery may not have enough memory installed.  

解析度

  1. Reboot the Data Domain system. If the issue persists, continue to step 2.
  2. Drain flea power from the Data Domain system:
    1. Power the Data Domain system down gracefully.
    2. Disconnect the server from all power and network cables.
    3. Hold down the power button continuously for at least ten seconds.
    4. Insert power and network cables back into the system.
    5. Wait two minutes before powering on the server to give the iDRAC time to initialize.
    6. Power the system on.
  3. Engineering recommends that older Data Domain systems be rebooted approximately every 3 months. This helps to prevent Ethernet driver allocation failure due to memory fragmentation.
  4. If the issue persists, contact Data Domain support.

其他資訊

Our engineering team is working on updates to the network card drivers and DDOS code to address the problem.

受影響的產品

Data Domain
文章屬性
文章編號: 000417138
文章類型: Solution
上次修改時間: 19 1月 2026
版本:  1