Data Domain: RPM Upload Failure on GUI Exception error occurred
摘要: The GUI becomes unresponsive and RPM uploads fail because the iDRAC does not supply Secure Boot entries in host_bios.json, causing the sms_system_get_secure_boot API to error.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
Observed Symptoms
- Data Domain Web GUI is extremely slow or unresponsive.
- RPM package upload via the GUI fails after showing 95% progress. Error "There was an exception retrieving data. Please view your log files"
- Navigating to the Maintenance -> System page throws below error
- Log entry:
09 Jan 2026 11:49:59,972 ERROR [xxx-xxx-127.0.0.1-8009-exec-563] An exception occurred while handling a client request com.datadomain.webf.shared.sms.SMException:
- Backend logs show
ERROR: pta_json_get_specific_obj: error parsing JSON object SecureBoot ERROR: pta_json_file_get_object: failed to get JSON object value ERROR: plat_pta_secure_boot_get_status: Secure Boot: failed to get object "SecureBoot" ERROR: Failed to get Secure Boot status, rc = 8
原因
Root Cause Analysis
The Data Domain Web GUI becomes unresponsive and RPM uploads fail because the host_bios.json file retrieved from the iDRAC does not contain the required Secure Boot fields. The missing fields cause the sms_system_get_secure_boot API call to throw exceptions, preventing the GUI from completing the upload workflow.
Contributing Factors
- The DDOS component relies on the HOSA REST API to obtain Secure Boot status; without the JSON entries, the API returns an I/O error.
- Resulting error propagates to the web server, leading to the observed “Exception error occurred” message
解析度
Resolution Steps
- Reset the iDRAC to restore proper BIOS JSON provisioning.
- Verify GUI responsiveness and retry the RPM upload via the GUI
- If the issue persists, collect System Update Package (SUB) logs for deeper analysis and contact Dell Support.