PowerEdge:R740 - 新增記憶體後,多個記憶體回報多位元錯誤 (MBE)
摘要: R740 原有記憶體已升級為 24X128G 組態。 升級完成後,除 A1 B1 之外的所有記憶體都會回報 MBE 錯誤。將其他插槽記憶體更換至 A1 B1 進行測試。記憶體沒有出現問題。
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
2021-10-29 06:41:29 Multi-bit memory errors detected on a memory device at location(s) DIMM_B12. 2021-10-29 06:41:29 Multi-bit memory errors detected on a memory device at location(s) DIMM_B6. 2021-10-29 06:41:29 Multi-bit memory errors detected on a memory device at location(s) DIMM_B11. 2021-10-29 06:41:29 Multi-bit memory errors detected on a memory device at location(s) DIMM_B5. 2021-10-29 06:41:28 Multi-bit memory errors detected on a memory device at location(s) DIMM_B10. 2021-10-29 06:41:28 Multi-bit memory errors detected on a memory device at location(s) DIMM_B4. 2021-10-29 06:41:28 Multi-bit memory errors detected on a memory device at location(s) DIMM_B9. 2021-10-29 06:41:27 Multi-bit memory errors detected on a memory device at location(s) DIMM_B3. 2021-10-29 06:41:27 Multi-bit memory errors detected on a memory device at location(s) DIMM_B8. 2021-10-29 06:41:27 Multi-bit memory errors detected on a memory device at location(s) DIMM_B2.
檢查 TSR 記錄,當記憶體中回報 MBE 錯誤時,也會出現UEFI0355錯誤。資訊如下。
2021-10-29 19:41:41 496 UEFI0355 All the NVDIMMs are disabled because the value of memory capacity of all the installed NVDIMMs has exceeded the maximum value supported by the processor.
原因
再次檢查支援的已用 CPU 記憶體大小。
使用的 CPU 為 Xeon 黃金級 5218 X2。
單個 CPU 支援 1 TB 記憶體大小。
在此配置下,2 個 CPU 最多可支援 2 TB 的記憶體。
伺服器的記憶體容量已超出 CPU 的支援範圍。
解析度
將記憶體容量降低至 2 TB。
根據安裝與維修手冊中的系統記憶體指引來安裝記憶體。
受影響的產品
OEMR R740, PowerEdge R740文章屬性
文章編號: 000193244
文章類型: Solution
上次修改時間: 26 5月 2025
版本: 3
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。