Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

RRDU Event Messages

RRDU0001

Message
Internal Dual SD Module is redundant.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 3 (Informational)
Trap/EventID
2491
OMSA Event ID
5304
OMSA Trap ID
5304
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

RRDU0002

Message
Internal Dual SD Module redundancy is lost.
Detailed Description
Either one of the SD card or both the SD cards are not functioning properly.
Recommended Response Action
Replace the failed SD card.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 1 (Critical)
Trap/EventID
2489
LCD Message
Internal Dual SD Module redundancy lost. Check SD cards
OMSA Event ID
5306
OMSA Trap ID
5306
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

RRDU0003

Message
Internal Dual SD Module redundancy is degraded.
Detailed Description
Either one of the SD card or both the SD cards are not functioning properly.
Recommended Response Action
Replace the failed SD card.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 2 (Warning)
Trap/EventID
2490
OMSA Event ID
5305
OMSA Trap ID
5305
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

RRDU0004

Message
Internal Dual SD Module is not redundant.
Detailed Description
None
Recommended Response Action
Install additional SD card and configure for redundancy if redundancy is desired.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 3 (Informational)
Trap/EventID
2491
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

RRDU0005

Message
Internal Dual SD Module is not redundant. Insufficient resources to maintain normal operations.
Detailed Description
The current operating configuration cannot maintain redundancy.The unit may operate in a degraded state.
Recommended Response Action
Review product documentation and SD card configuration.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 1 (Critical)
LCD Message
Internal Dual SD Module is not redundant. Insufficient resources. Check SD Cards
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

RRDU0006

Message
Internal Dual SD Module rebuild initiated.
Detailed Description
Internal Dual SD Module rebuild initiated.
Recommended Response Action
No response action is required.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 3 (Informational)
Trap/EventID
2491
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

RRDU0007

Message
Internal Dual SD Module rebuild completed successfully.
Detailed Description
Internal Dual SD Module rebuild completed successfully.
Recommended Response Action
No response action is required.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 3 (Informational)
Trap/EventID
2491
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

RRDU0008

Message
Internal Dual SD Module rebuild did not complete successfully.
Detailed Description
Internal Dual SD Module rebuild failed because read/write to one of the SD cards failed.
Recommended Response Action
Replace the failed SD card and retry rebuild.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 1 (Critical)
Trap/EventID
2489
LCD Message
Internal Dual SD Module rebuild failed. Replace failed SD card.
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*        
CMC              

RRDU0010

Message
Internal SD Module redundancy is disabled.
Detailed Description
Redundancy is not currently enabled for the Internal SD Module.
Recommended Response Action
No response action is required.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 3 (Informational)
OMSA Event ID
5302
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

RRDU0011

Message
Unable to determine the redundancy status of the Internal SD Module.
Detailed Description
This occurs because of one of the following reasons: 1) Either one of the SD card or both the SD cards have failed. 2) The Internal SD Module has failed.
Recommended Response Action
Replace the failed SD card with a new SD card, or replace the Internal SD Module. For more information, contact your service provider.
Category
System Health (RRDU = IDSDM Redundancy)
Severity
Severity 2 (Warning)
OMSA Event ID
5301
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\